Your browser doesn't support javascript.
loading
Ratiometric fluorescence nanoprobe based on carbon dots and terephthalic acid for determining Fe2+ in environmental samples.
Wang, Huaxin; Fu, Ting; Ai, Mimi; Liu, Jinshui.
Afiliação
  • Wang H; College of Chemistry and Materials Science, The Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Laboratory of Molecule-Based Materials, Anhui Normal University, Wuhu, 241000, China.
  • Fu T; College of Chemistry and Materials Science, The Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Laboratory of Molecule-Based Materials, Anhui Normal University, Wuhu, 241000, China.
  • Ai M; College of Chemistry and Materials Science, The Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Laboratory of Molecule-Based Materials, Anhui Normal University, Wuhu, 241000, China.
  • Liu J; College of Chemistry and Materials Science, The Key Laboratory of Functional Molecular Solids, Ministry of Education, Anhui Laboratory of Molecule-Based Materials, Anhui Normal University, Wuhu, 241000, China. jsliu@sina.com.
Anal Bioanal Chem ; 414(23): 6735-6741, 2022 Sep.
Article em En | MEDLINE | ID: mdl-35864267
ABSTRACT
A ratiometric fluorescent nanoprobe using carbon dots (CDs) and involving oxidation of terephthalic acid (TPA) induced by hydroxyl radicals (·OH) was developed for sensitively and selectively determining Fe2+ ions. When Fe2+ ions are added to the TPA@CDs/H2O2 system, ·OH produced through the Fenton reaction oxidizes the non-fluorescent TPA to give 2-hydroxyl terephthalic acid, which fluoresces at 423 nm when excited at 286 nm. The ·OH and Fe3+ produced quench CD fluorescence at 326 nm. The 2-hydroxyl terephthalic acid to CD fluorescence intensity ratio linearly increased as the Fe2+ concentration increased in the range 0.5-50 µM, and the detection limit was 0.25 µM. The new assay is very selective because it involves dual-emission reverse change ratio fluorescence sensing, which can exclude matrix effects. The new nanoprobe was used to determine Fe2+ concentrations in real water samples, and the recoveries were found to be acceptable. Schematic of the ratiometric fluorometric method for determining Fe2+ based on CDs and TPA.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácidos Ftálicos / Pontos Quânticos Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácidos Ftálicos / Pontos Quânticos Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China