Your browser doesn't support javascript.
loading
NaCl Ionization-Based Moisture Sensor Prepared by Aerosol Deposition for Monitoring Respiratory Patterns.
Cho, Myung-Yeon; Kim, Ik-Soo; Kim, Min-Ji; Hyun, Da-Eun; Koo, Sang-Mo; Sohn, Hiesang; Kim, Nam-Young; Kim, Sunghoon; Ko, Seunghoon; Oh, Jong-Min.
Afiliação
  • Cho MY; Department of Electronic Materials Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea.
  • Kim IS; Department of Materials Science and Engineering, Pohang University of Science and Technology, 77 Cheongam-ro, Pohang 37673, Korea.
  • Kim MJ; Department of Electronic Materials Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea.
  • Hyun DE; Department of Electronic Materials Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea.
  • Koo SM; Department of Electronic Materials Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea.
  • Sohn H; Department of Chemical Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea.
  • Kim NY; RFIC Center, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea.
  • Kim S; Department of Applied Chemistry, Dong-Eui University, Busan 47227, Korea.
  • Ko S; Department of Electronic Materials Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea.
  • Oh JM; Department of Electronic Materials Engineering, Kwangwoon University, 20 Kwangwoon-ro, Nowon-gu, Seoul 01897, Korea.
Sensors (Basel) ; 22(14)2022 Jul 11.
Article em En | MEDLINE | ID: mdl-35890859
ABSTRACT
A highly polarizable moisture sensor with multimodal sensing capabilities has great advantages for healthcare applications such as human respiration monitoring. We introduce an ionically polarizable moisture sensor based on NaCl/BaTiO3 composite films fabricated using a facile aerosol deposition (AD) process. The proposed sensing model operates based on an enormous NaCl ionization effect in addition to natural moisture polarization, whereas all previous sensors are based only on the latter. We obtained an optimal sensing performance in a 0.5 µm-thick layer containing NaCl-37.5 wt% by manipulating the sensing layer thickness and weight fraction of NaCl. The NaCl/BaTiO3 sensing layer exhibits outstanding sensitivity over a wide humidity range and a fast response/recovery time of 2/2 s; these results were obtained by performing the one-step AD process at room temperature without using any auxiliary methods. Further, we present a human respiration monitoring system using a sensing device that provides favorable and stable electrical signals under diverse respiratory scenarios.