Your browser doesn't support javascript.
loading
Speech recognition as a function of the number of channels for Mid-Scala electrode array recipients.
Berg, Katelyn A; Noble, Jack H; Dawant, Benoit M; Dwyer, Robert T; Labadie, Robert F; Gifford, René H.
Afiliação
  • Berg KA; Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA.
  • Noble JH; Department of Electrical Engineering and Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA.
  • Dawant BM; Department of Electrical Engineering and Computer Science, Vanderbilt University, 2201 West End Avenue, Nashville, Tennessee 37235, USA.
  • Dwyer RT; Advanced Bionics, 28515 Westinghouse Place, Valencia, California 91355, USA.
  • Labadie RF; Department of Otolaryngology, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA.
  • Gifford RH; Department of Hearing and Speech Sciences, Vanderbilt University Medical Center, 1215 21st Avenue South, Nashville, Tennessee 37232, USA.
J Acoust Soc Am ; 152(1): 67, 2022 07.
Article em En | MEDLINE | ID: mdl-35931512
ABSTRACT
This study investigated the number of channels needed for maximum speech understanding and sound quality in 15 adult cochlear implant (CI) recipients with Advanced Bionics (AB) Mid-Scala electrode arrays completely within scala tympani. In experiment I, CI programs used a continuous interleaved sampling (CIS)-based strategy and 4-16 active electrodes. In experiment II, CI programs used an n-of-m strategy featuring 16 active electrodes with either 8- or 12-maxima. Speech understanding and sound quality measures were assessed. For CIS programs, participants demonstrated performance gains using up to 4-10 electrodes on speech measures and sound quality ratings. For n-of-m programs, there was no significant effect of maxima, suggesting 8-maxima is sufficient for this sample's maximum performance and sound quality. These results are largely consistent with previous studies using straight electrode arrays [e.g., Fishman, Shannon, and Slattery (1997). J. Speech Lang. Hear. Res. 40, 1201-1215; Friesen, Shannon, Baskent, and Wang (2001). J. Acoust. Soc. Am. 110, 1150-1163; Shannon, Cruz, and Galvin (2011). Audiol. Neurotol. 16, 113-123; Berg, Noble, Dawant, Dwyer, Labadie, and Gifford (2020). J. Acoust. Soc. Am. 147, 3646-3656] and in contrast with recent studies looking at cochlear precurved electrode arrays [e.g., Croghan, Duran, and Smith (2017). J. Acoust. Soc. Am. 142, EL537-EL543; Berg, Noble, Dawant, Dwuer, Labadie, and Gifford (2019b). J. Acoust. Soc. Am. 145, 1556-1564], which found continuous improvements up to 16 independent channels. These findings suggest that Mid-Scala electrode array recipients demonstrate similar channel independence to straight electrode arrays rather than other manufacturer's precurved electrode arrays.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Percepção da Fala / Implantes Cocleares / Implante Coclear Limite: Adult / Humans Idioma: En Revista: J Acoust Soc Am Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Percepção da Fala / Implantes Cocleares / Implante Coclear Limite: Adult / Humans Idioma: En Revista: J Acoust Soc Am Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos