Your browser doesn't support javascript.
loading
Colorimetric nano-beacon and magnetic separation-based rapid and visual assay for gram-negative bacteria.
Yang, Beibei; Chen, Fei; Wang, Yi; Deng, Ting; Feng, Xinxin; Li, Jishan.
Afiliação
  • Yang B; State Key Laboratory of Chemo/Bio-Sensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, China.
  • Chen F; State Key Laboratory of Chemo/Bio-Sensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, China.
  • Wang Y; State Key Laboratory of Chemo/Bio-Sensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, China.
  • Deng T; Institute of Applied Chemistry, School of Science, Central South University of Forestry and Technology, Changsha, 410004, PR China.
  • Feng X; State Key Laboratory of Chemo/Bio-Sensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, China. Electronic address: xinxin_feng@hnu.edu.cn.
  • Li J; State Key Laboratory of Chemo/Bio-Sensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, China. Electronic address: jishanli@hnu.edu.cn.
Anal Biochem ; 655: 114824, 2022 10 15.
Article em En | MEDLINE | ID: mdl-35944695
ABSTRACT
Food-borne diseases caused by pathogenic bacteria are one of the serious factors affecting human health. However, the most commonly used detection methods for pathogenic bacteria not only require expensive instruments, but also take a long time due to the complicated and cumbersome detection process. Therefore, the development of a fast, simple, and low-cost detection method for pathogenic bacteria is crucial for food safety and human health. In this work, based on the high binding ability of antimicrobial peptide (AMP) and polymyxin B (PMB) to bacteria, combined with magnetic separation technology, a new enzyme-free colorimetric strategy was constructed to achieve visual detection of Gram-negative bacteria in complex samples. The sensor system was divided into the following two parts a colorimetric signal amplification nanoprobe, which was modified with AMP to enable effective binding of the colorimetric probe to the surface of bacteria, and a PMB-modified magnetic nanobead (MNB), which was used as the capture and enrichment unit of Gram-negative bacteria, as a result of which PMB could effectively distinguish Gram-negative bacteria from Gram-positive bacteria. Under optimized conditions, the detection limit of the method for Gram-negative bacteria (e.g. E. coli (G-)) was as low as 10 CFU/mL, and it was successfully applied to complex real samples. In addition, the developed colorimetric sensor offered advantages, such as fast response, less time consumption, high sensitivity, and low cost. It can be expected to become a new diagnostic tool for on-site detection of pathogenic bacteria in remote areas.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Colorimetria / Escherichia coli Limite: Humans Idioma: En Revista: Anal Biochem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Colorimetria / Escherichia coli Limite: Humans Idioma: En Revista: Anal Biochem Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China