Your browser doesn't support javascript.
loading
Low-cost high-resolution photoacoustic microscopy of blood oxygenation with two laser diodes.
Li, Xiufeng; Yeung, Kylie; Tsang, Victor T C; Huang, Bingxin; Lo, Claudia T K; Wong, Terence T W.
Afiliação
  • Li X; Translational and Advanced Bioimaging Laboratory, Department of Chemical and Biological Engineering, Hong Kong University of Science and Technology, Hong Kong, China.
  • Yeung K; Translational and Advanced Bioimaging Laboratory, Department of Chemical and Biological Engineering, Hong Kong University of Science and Technology, Hong Kong, China.
  • Tsang VTC; Department of Medical Physics and Biomedical Engineering, University College London, Gower Street, London WC1E 6BT, UK.
  • Huang B; Translational and Advanced Bioimaging Laboratory, Department of Chemical and Biological Engineering, Hong Kong University of Science and Technology, Hong Kong, China.
  • Lo CTK; Translational and Advanced Bioimaging Laboratory, Department of Chemical and Biological Engineering, Hong Kong University of Science and Technology, Hong Kong, China.
  • Wong TTW; Translational and Advanced Bioimaging Laboratory, Department of Chemical and Biological Engineering, Hong Kong University of Science and Technology, Hong Kong, China.
Biomed Opt Express ; 13(7): 3893-3903, 2022 Jul 01.
Article em En | MEDLINE | ID: mdl-35991932
ABSTRACT
Optical-resolution photoacoustic microscopy (OR-PAM) has been widely used for imaging blood vessel and oxygen saturation of hemoglobin (sO2), providing high-resolution functional images of living animals in vivo. However, most of them require one or multiple bulky and costly pulsed lasers, hindering their applicability in preclinical and clinical settings. In this paper, we demonstrate a reflection-mode low-cost high-resolution OR-PAM system by using two cost-effective and compact laser diodes (LDs), achieving microvasculature and sO2 imaging with a high lateral resolution of ∼6 µm. The cost of the excitation sources has dramatically reduced by ∼20-40 times compared to that of the pulsed lasers used in state-of-the-art OR-PAM systems. A blood phantom study was performed to show a determination coefficient R 2 of 0.96 in linear regression analysis. Experimental results of in vivo mouse ear imaging show that the proposed dual-wavelength LD-based PAM system can provide high-resolution functional images at a low cost.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Health_economic_evaluation Idioma: En Revista: Biomed Opt Express Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Health_economic_evaluation Idioma: En Revista: Biomed Opt Express Ano de publicação: 2022 Tipo de documento: Article País de afiliação: China