Cloud-based fusion imaging improves operative metrics during fenestrated endovascular aneurysm repair.
J Vasc Surg
; 77(2): 366-373, 2023 Feb.
Article
em En
| MEDLINE
| ID: mdl-36181994
OBJECTIVE: Endovascular treatment of complex aortic pathology has been associated with increases in procedural-related metrics, including the operative time and radiation exposure. Three-dimensional fusion imaging technology has decreased the radiation dose and iodinated contrast use during endovascular aneurysm repair. The aim of the present study was to report our institutional experience with the use of a cloud-based fusion imaging platform during fenestrated endovascular aneurysm repair (FEVAR). METHODS: A retrospective review of a prospectively maintained aortic database was performed to identify all patients who had undergone FEVAR with commercially available devices (Zenith Fenestrated; Cook Medical Inc, Bloomington, IN) between 2013 and 2020 and all endovascular aneurysm repairs performed using Cydar EV Intelligent Maps (Cydar Medical, Cambridge, UK). The Cydar EV cohort was reviewed further to select all FEVARs performed with overlay map guidance. The patient demographic, clinical, and procedure metrics were analyzed, with a comparative analysis of FEVAR performed without and with the Cydar EV imaging platform. Patients were excluded from comparative analysis if the data were incomplete in the dataset or they had a documented history of prior open or endovascular abdominal aortic aneurysm repair. RESULTS: During the 7-year study period, 191 FEVARs had been performed. The Cydar EV imaging platform was implemented in 2018 and used in 124 complex endovascular aneurysm repairs, including 69 consecutive FEVARs. A complete dataset was available for 137 FEVARs. With exclusion to select for de novo FEVAR, a comparative analysis was performed of 53 FEVAR without and 63 with Cydar EV imaging guidance. The cohorts were similar in patient demographics, medical comorbidities, and aortic aneurysm characteristics. No significant difference was noted between the two groups for major adverse postoperative events, length of stay, or length of intensive care unit stay. The use of Cydar EV resulted in nonsignificant decreases in the mean fluoroscopy time (69.3 ± 28 minutes vs 66.2 ± 33 minutes; P = .598) and operative time (204.4 ± 64 minutes vs 186 ± 105 minutes; P = .278). A statistically significant decrease was found in the iodinated contrast volume (105 ± 44 mL vs 83 ± 32 mL; P = .005), patient radiation exposure using the dose area product (1,049,841 mGy/cm2 vs 630,990 mGy/cm2; P < .001) and cumulative air kerma levels (4518 mGy vs 3084 mGy; P = .02) for patients undergoing FEVAR with Cydar EV guidance. CONCLUSIONS: At our aortic center, we have observed a trend toward shorter operative times and significant reductions in both iodinated contrast use and radiation exposure during FEVAR using the Cydar EV intelligent maps. Intelligent map guidance improved the efficiency of complex endovascular aneurysm repair, providing a safer intervention for both patient and practitioner.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Aneurisma da Aorta Abdominal
/
Implante de Prótese Vascular
/
Procedimentos Endovasculares
Tipo de estudo:
Guideline
/
Prognostic_studies
Limite:
Humans
Idioma:
En
Revista:
J Vasc Surg
Assunto da revista:
ANGIOLOGIA
Ano de publicação:
2023
Tipo de documento:
Article