Your browser doesn't support javascript.
loading
Comparison of FreeSurfer and CAT12 Software in Parcel-Based Cortical Thickness Calculations.
Ay, Ulas; Kizilates-Evin, Gozde; Bayram, Ali; Kurt, Elif; Demiralp, Tamer.
Afiliação
  • Ay U; Graduate School of Health Sciences, Istanbul University, Süleymaniye Mah. Bozdogan Kemeri Cd, Vezneciler Hamami Sk No:8, 34126, Istanbul, Turkey. psk.ulasay@gmail.com.
  • Kizilates-Evin G; Department of Neuroscience, Aziz Sancar Institute of Experimental Medicine, Istanbul University, Topkapi Mah. Turgut Özal Millet Cd No:118, 34093, Istanbul, Turkey. psk.ulasay@gmail.com.
  • Bayram A; Neuroimaging Unit, Hulusi Behcet Life Sciences Research Laboratory, Neuroimaging Unit, Istanbul University, Topkapi Mah. Turgut Özal Millet Cd No:118, 34093, Istanbul, Turkey. psk.ulasay@gmail.com.
  • Kurt E; Department of Neuroscience, Aziz Sancar Institute of Experimental Medicine, Istanbul University, Topkapi Mah. Turgut Özal Millet Cd No:118, 34093, Istanbul, Turkey.
  • Demiralp T; Neuroimaging Unit, Hulusi Behcet Life Sciences Research Laboratory, Neuroimaging Unit, Istanbul University, Topkapi Mah. Turgut Özal Millet Cd No:118, 34093, Istanbul, Turkey.
Brain Topogr ; 35(5-6): 572-582, 2022 11.
Article em En | MEDLINE | ID: mdl-36208399
Several approaches have emerged to measure the cortical thickness (CT), which can be broadly divided into surface-based and voxel-based algorithms. We aimed to compare parcel-based CT estimation of the widely used FreeSurfer (FS) software and CAT12 software, which is a widely used voxel-based approach, and evaluate the test-retest (TRT) reliability of both methods. MRI images of 417 healthy individuals were analyzed. TRT reliability was performed on 60 participants. The mean CT of the parcels of the Desikan-Killiany atlas were calculated both in FS and CAT12. Linear mixed model was performed to compare the two methods and the TRT reliability, and paired-sample t-test for post-hoc analyses. Linear regression analyses were utilized to examine the regressions between the two methods and between different sessions with each method. CT values calculated using the two methods were significantly correlated (R2adj = 0.67). The significant interaction effect between the method and the parcels were due to larger CT values of FS in 32 of 68 parcels, whereas CT values of CAT12 were higher in 31 of 68 parcels. The TRT reliabilities of both approaches were excellent (FS R2adj = 0.95, CAT12 R2adj = 0.93). We conclude that both techniques can provide equally valid results for groups comparisons or follow-up studies as long as they are not mixed with each other.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Software / Imageamento por Ressonância Magnética Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Brain Topogr Assunto da revista: CEREBRO Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Software / Imageamento por Ressonância Magnética Tipo de estudo: Observational_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Brain Topogr Assunto da revista: CEREBRO Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Turquia