Your browser doesn't support javascript.
loading
Intra-operator Repeatability of Manual Segmentations of the Hip Muscles on Clinical Magnetic Resonance Images.
Davico, Giorgio; Bottin, Francesca; Di Martino, Alberto; Castafaro, Vanita; Baruffaldi, Fabio; Faldini, Cesare; Viceconti, Marco.
Afiliação
  • Davico G; Department of Industrial Engineering (DIN), Alma Mater Studiorum - University of Bologna, Bologna, Italy. giorgio.davico@unibo.it.
  • Bottin F; Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy. giorgio.davico@unibo.it.
  • Di Martino A; Department of Industrial Engineering (DIN), Alma Mater Studiorum - University of Bologna, Bologna, Italy.
  • Castafaro V; Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
  • Baruffaldi F; Clinica Ortopedica e Traumatologica I, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
  • Faldini C; Department of Biomedical and Neuromotor Sciences (DIBINEM), Alma Mater Studiorum - University of Bologna, Bologna, Italy.
  • Viceconti M; Clinica Ortopedica e Traumatologica I, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
J Digit Imaging ; 36(1): 143-152, 2023 02.
Article em En | MEDLINE | ID: mdl-36219348
ABSTRACT
The manual segmentation of muscles on magnetic resonance images is the gold standard procedure to reconstruct muscle volumes from medical imaging data and extract critical information for clinical and research purposes. (Semi)automatic methods have been proposed to expedite the otherwise lengthy process. These, however, rely on manual segmentations. Nonetheless, the repeatability of manual muscle volume segmentations performed on clinical MRI data has not been thoroughly assessed. When conducted, volumetric assessments often disregard the hip muscles. Therefore, one trained operator performed repeated manual segmentations (n = 3) of the iliopsoas (n = 34) and gluteus medius (n = 40) muscles on coronal T1-weighted MRI scans, acquired on 1.5 T scanners on a clinical population of patients elected for hip replacement surgery. Reconstructed muscle volumes were divided in sub-volumes and compared in terms of volume variance (normalized variance of volumes - nVV), shape (Jaccard Index-JI) and surface similarity (maximal Hausdorff distance-HD), to quantify intra-operator repeatability. One-way repeated measures ANOVA (or equivalent) tests with Bonferroni corrections for multiple comparisons were conducted to assess statistical significance. For both muscles, repeated manual segmentations were highly similar to one another (nVV 2-6%, JI > 0.78, HD < 15 mm). However, shape and surface similarity were significantly lower when muscle extremities were included in the segmentations (e.g., iliopsoas HD -12.06 to 14.42 mm, P < 0.05). Our findings show that the manual segmentation of hip muscle volumes on clinical MRI scans provides repeatable results over time. Nonetheless, extreme care should be taken in the segmentation of muscle extremities.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Músculos Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: J Digit Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM / INFORMATICA MEDICA / RADIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Músculos Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: J Digit Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM / INFORMATICA MEDICA / RADIOLOGIA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Itália