Your browser doesn't support javascript.
loading
Enhancing Electrochemical Biosensor Performance for 17ß-Estradiol Determination with Short Split-Aptamers.
Rozi, Normazida; Hanifah, Sharina Abu; Abd Karim, Nurul Huda; Heng, Lee Yook; Higashi, Sayuri L; Ikeda, Masato.
Afiliação
  • Rozi N; Department of Chemical Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia.
  • Hanifah SA; Department of Chemical Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia.
  • Abd Karim NH; Polymer Research Centre, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia.
  • Heng LY; Department of Chemical Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia.
  • Higashi SL; Department of Chemical Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor, Malaysia.
  • Ikeda M; Department of Chemistry and Biomolecular Science, Faculty of Engineering, Gifu University, 1-1 Yanagido, Gifu 501-1193, Japan.
Biosensors (Basel) ; 12(12)2022 Nov 25.
Article em En | MEDLINE | ID: mdl-36551044
ABSTRACT
Chronic exposure of 17ß-estradiol (E2) even at low concentration can disorganize the endocrine system and lead to undesirable health problems in the long run. An electrochemical biosensor for rapid detection of E2 in water samples was successfully developed. The biosensor was based on split DNA aptamers attached onto poly (methacrylic acid-co-n butyl acrylate-succinimide) microspheres deposited on polypyrrole nanowires coated electrode (PPY/PMAA-NBA). The sandwich paired of split DNA aptamers used were truncated from 75 mer parent aptamers. These two strands of 12-mer and 14-mer split DNA aptamers were then immobilized on the PMAA-NBA microspheres. In the presence of E2, the split DNA aptamers formed an apt12-E2-apt14 complex, where the binding reaction on the electrode surface led to the detection of E2 by differential pulse voltammetry using ferrocyanide as a redox indicator. Under optimum conditions, the aptasensor detected E2 concentrations in the range of 1 × 10-4 M to 1 × 10-12 M (R2 = 0.9772) with a detection limit of 4.8 × 10-13 M. E2, which were successfully measured in a real sample with 97-104% recovery and showed a good correlation (R2 = 0.9999) with the established method, such as high-performance liquid chromatography. Interactions between short and sandwich-type aptamers (split aptamers) demonstrated improvement in aptasensor performance, especially the selectivity towards several potential interferents.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Aptâmeros de Nucleotídeos / Nanopartículas Metálicas Idioma: En Revista: Biosensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Malásia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Aptâmeros de Nucleotídeos / Nanopartículas Metálicas Idioma: En Revista: Biosensors (Basel) Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Malásia