Your browser doesn't support javascript.
loading
Samarium-Based Turn-Off Fluorescence Sensor for Sensitive and Selective Detection of Quinolinic Acid in Human Urine and Serum.
Zhang, Bao-Ding; Liu, Bing; Yin, Yu-Xing; Xu, Ling.
Afiliação
  • Zhang BD; College of Chemistry and Chemical Engineering, Shaanxi Key Laboratory of Chemical Additives for Industry, Shaanxi University of Science and Technology, Xi'an 710021, Shaanxi Province, P. R. China.
  • Liu B; College of Chemistry and Chemical Engineering, Shaanxi Key Laboratory of Chemical Additives for Industry, Shaanxi University of Science and Technology, Xi'an 710021, Shaanxi Province, P. R. China.
  • Yin YX; College of Chemistry and Chemical Engineering, Shaanxi Key Laboratory of Chemical Additives for Industry, Shaanxi University of Science and Technology, Xi'an 710021, Shaanxi Province, P. R. China.
  • Xu L; Key Laboratory of Macromolecular Science of Shaanxi Province, Shaanxi Key Laboratory for Advanced Energy Devices, Shaanxi Engineering Laboratory for Advanced Energy Technology, School of Chemistry & Chemical Engineering, Shaanxi Normal University, Xi'an 710062, Shaanxi Province, P. R. China.
Inorg Chem ; 62(2): 1007-1017, 2023 Jan 16.
Article em En | MEDLINE | ID: mdl-36584325
Quinolinic acid (QA) is an index for some diseases, whose detection is of importance. This work presents a samarium metal-organic framework (Sm-MOF) containing 5-sulfoisophthalate ligand (SIP3-). The fluorescence of Sm-MOF integrates the emission at 339 nm from the SIP3- ligand and four characteristic 4G5/2 → 4Hj (j = 5/2, 7/2, 9/2, and 11/2) transitions at 559, 596, 642, and 701 nm from Sm(III). Sm-MOF as a turn-off fluorescence sensor to QA exhibits high sensitivity, selectivity, and durability. The fluorescence quenching response to QA shows a linear relationship of I0/I = 0.00496·CQA + 1.12474 in the QA concentration of 0-500 µM and a limit of detection calculated as 4.11 µM. Sm-MOF shows the structural and fluorescent stabilities in five quenching-recovery cycles. The recoveries of close to 100% in human urine and serum indicate high reliability. The paper-based Sm-MOF sensor displays a rough QA quantitative analysis by recognizing red values in the on-site QA detection.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Samário / Estruturas Metalorgânicas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Inorg Chem Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Samário / Estruturas Metalorgânicas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Inorg Chem Ano de publicação: 2023 Tipo de documento: Article