Your browser doesn't support javascript.
loading
Dry Chemistry-Based Bipolar Electrochemiluminescence Immunoassay Device for Point-of-Care Testing of Alzheimer-Associated Neuronal Thread Protein.
Liang, Yi; Xue, Kaifa; Shi, Yanyang; Zhan, Tingting; Lai, Wei; Zhang, Chunsun.
Afiliação
  • Liang Y; MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
  • Xue K; MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
  • Shi Y; MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
  • Zhan T; MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
  • Lai W; MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
  • Zhang C; MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou 510631, China.
Anal Chem ; 95(6): 3434-3441, 2023 02 14.
Article em En | MEDLINE | ID: mdl-36719948
ABSTRACT
In this study, we developed, for the first time, a novel dry chemistry-based bipolar electrochemiluminescence (ECL) immunoassay device for point-of-care testing (POCT) of Alzheimer-associated neuronal thread protein (AD7c-NTP), where the ECL signals were automatically collected and analyzed after the sample and buffer solutions were manually added onto the immunosensor. The proposed immunoassay device contains an automatic ECL analyzer and a dry chemistry-based ECL immunosensor fabricated with a screen-printed fiber material-based chip and a three-dimensional (3D)-printed shell. Each pad of the fiber material-based chip was premodified with certain reagents for immunoreaction and then assembled to form the ECL immunosensor. The self-enhanced ECL of the Ru(II)-poly-l-lysine complex and the lateral flow fiber material-based chip make the addition of coreactants and repeated flushing unnecessary. Only the sample and buffer solutions are added to the ECL immunosensor, and the process of ECL detection can be completed in about 6 min using the proposed automatic ECL analyzer. Under optimized conditions, the linear detection range for AD7c-NTP was 1 to 104 pg/mL, and the detection limit was 0.15 pg/mL. The proposed ECL immunoassay device had acceptable selectivity, stability, and reproducibility and had been successfully applied to detect AD7c-NTP levels in human urine. In addition, the accurate detection of AD7c-NTP and duplex detection of AD7c-NTP and apolipoprotein E ε4 gene were also validated. It is believed that the proposed ECL immunoassay device may be a candidate for future POCT applications.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Doença de Alzheimer Tipo de estudo: Diagnostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Doença de Alzheimer Tipo de estudo: Diagnostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: Anal Chem Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China