Your browser doesn't support javascript.
loading
Impact of total cerebral small vessel disease score on ophthalmic artery morphologies and hemodynamics.
Wang, Jia-Lin; Cheng, Xue-Ru; Meng, Zhao-Yang; Wang, Yan-Ling.
Afiliação
  • Wang JL; Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, 95 Yong'an Road, Xicheng District, Beijing, 100050, China. wangjialin@bjmu.edu.cn.
  • Cheng XR; Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, 95 Yong'an Road, Xicheng District, Beijing, 100050, China.
  • Meng ZY; Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, 95 Yong'an Road, Xicheng District, Beijing, 100050, China. mm1526@ccmu.edu.cn.
  • Wang YL; Department of Ophthalmology, Beijing Friendship Hospital, Capital Medical University, 95 Yong'an Road, Xicheng District, Beijing, 100050, China. wangyanl@ccmu.edu.cn.
J Transl Med ; 21(1): 65, 2023 02 01.
Article em En | MEDLINE | ID: mdl-36726156
BACKGROUND: Cerebral small vessel disease (CSVD) is a systemic disease, affecting not only the brain, but also eyes and other organs. The total CSVD score is a tool for comprehensive evaluation of brain lesions in patients with CSVD. The ophthalmic artery (OA) is a direct response to ocular blood flow. However, little is known about the correlation between CSVD and characteristics of OA. We investigated the OA morphologies and hemodynamics in patients with CSVD and the correlation between these changes and the total CSVD score. METHODS: This cross-sectional observational study included 34 eyes from 22 patients with CSVD and 10 eyes from 5 healthy controls. The total CSVD score was rated according to the CSVD signs on magnetic resonance imaging. OA morphological characteristics were measured on the basis of 3D OA model reconstruction. OA hemodynamic information was calculated using computational fluid dynamics simulations. RESULTS: The total CSVD score negatively correlated with the OA diameter, blood flow velocity, and mass flow ratio (all P < 0.05). After adjusting for potential confounding factors, the total CSVD score was still independently correlated with the OA blood velocity (ß = - 0.202, P = 0.005). The total CSVD score was not correlated with OA angle (P > 0.05). The presence of cerebral microbleeds and enlarged perivascular spaces was correlated with the OA diameter (both P < 0.01), while the lacunar infarcts and white matter hyperintensities were correlated with the OA blood velocity (both P < 0.001). CONCLUSIONS: The decrease of the blood velocity in the OA was associated with the increase in the total CSVD score. The changes of the OA diameter and velocity were associated with the presence of various CSVD signs. The findings suggest that more studies are needed in the future to evaluate CSVD by observing the morphologies and hemodynamics of OA.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças de Pequenos Vasos Cerebrais / Acidente Vascular Cerebral Lacunar Tipo de estudo: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: J Transl Med Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças de Pequenos Vasos Cerebrais / Acidente Vascular Cerebral Lacunar Tipo de estudo: Observational_studies / Prevalence_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: J Transl Med Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China