Your browser doesn't support javascript.
loading
Impact of crossplay between ocular aberrations and depth of focus in topo-guided laser-assisted in situ keratomileusis outcomes.
Khamar, Pooja; Shetty, Rohit; Annavajjhala, Sriram; Narasimhan, Raghav; Kumari, Savitri; Sathe, Priyanka; Roy, Abhijit Sinha.
Afiliação
  • Khamar P; Department of Cataract and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India.
  • Shetty R; Department of Cornea and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India.
  • Annavajjhala S; Department of Cornea and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India.
  • Narasimhan R; IBMS LAB, Narayana Nethralaya Foundation, Bengaluru, Karnataka, India.
  • Kumari S; Department of Cataract and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India.
  • Sathe P; Department of Cornea and Refractive Surgery, Narayana Nethralaya, Bengaluru, Karnataka, India.
  • Roy AS; IBMS LAB, Narayana Nethralaya Foundation, Bengaluru, Karnataka, India.
Indian J Ophthalmol ; 71(2): 467-475, 2023 02.
Article em En | MEDLINE | ID: mdl-36727342
Purpose: To develop a nomogram in cases with mismatch between subjective and Topolyzer cylinder, and based on the magnitude of the mismatch, customize a treatment plan to attain good visual outcomes post-laser-assisted in situ keratomileusis (LASIK) surgery. Methods: The patients were evaluated preoperatively using corneal tomography with Pentacam. Five optimal corneal topography scans were obtained from the Topolyzer Vario were used for planning the LASIK treatment. For the nomogram purpose, the patients were divided into three categories based on the difference between the subjective cylinder and Topolyzer (corneal) cylinder. The first group (group 1) consisted of eyes of patients, where the difference was less than or equal to 0.4 D. The second group (group 2) consisted of eyes, where the difference was more than 0.4 D and the subjective cylinder was lesser than the Topolyzer cylinder. The third group (group 3) included eyes where the difference was more than 0.4 D but the subjective cylinder was greater than the Topolyzer cylinder. LASIK was performed with the WaveLight FS 200 femtosecond laser and WaveLight EX500 excimer laser. Assessment of astigmatism correction for the three groups was done using Aplins vector analysis. For comparison of proportions, Chi-square test was used. A P value less than 0.05 was considered statistically significant. Results: The UDVA was statistically significantly different when compared between groups 1 and 2 (P = 0.02). However, the corrected distance visual acuity (CDVA) was similar among all the three groups (P = 0.1). Group 3 showed an increase of residual cylinder by -0.25 D, which was significant at intermediate and near reading distances (P < 0.05). Group 3 showed significantly higher target-induced astigmatism (TIA) compared to groups 1 and 2 (P = 0.01). The mean surgically induced astigmatism (SIA) was the least in group 2, which was statistically significant (P < 0.01). Conclusion: The outcomes for distance vision using our nomogram postoperatively were excellent, but further refinement for improving the near vision outcomes is required.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Astigmatismo / Ceratomileuse Assistida por Excimer Laser In Situ Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Revista: Indian J Ophthalmol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Astigmatismo / Ceratomileuse Assistida por Excimer Laser In Situ Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Humans Idioma: En Revista: Indian J Ophthalmol Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia