Your browser doesn't support javascript.
loading
Experimental Study of Deep Submersible Structure Defect Monitoring Based on Flexible Interdigital Transducer Surface Acoustic Wave Technology.
Ding, Zhongjun; Feng, Zhiliang; Li, Hongyu; Meng, Dejian; Zhang, Yi; Li, Dewei.
Afiliação
  • Ding Z; National Deep Sea Center, Qingdao 266237, China.
  • Feng Z; National Deep Sea Center, Qingdao 266237, China.
  • Li H; College of Ocean Science and Engineering, Shandong University of Science and Technology, Qingdao 266590, China.
  • Meng D; College of Ocean Science and Engineering, Shandong University of Science and Technology, Qingdao 266590, China.
  • Zhang Y; National Deep Sea Center, Qingdao 266237, China.
  • Li D; College of Ocean Science and Engineering, Shandong University of Science and Technology, Qingdao 266590, China.
Sensors (Basel) ; 23(3)2023 Jan 20.
Article em En | MEDLINE | ID: mdl-36772224
ABSTRACT
In view of the shortage of structural defect monitoring methods for deep submersibles, numerical simulation and experimental research on underwater SAW propagation based on interdigital transducers are carried out in this paper. PVDF interdigital transducer (PVDF-IDT) has shown considerable potential in the application of structural health monitoring because of its micro size, soft material characteristics, and the characteristics of long-term bonding on the surface of the tested structure. In order to realize the application of IDT on submersible or underwater structures, it is necessary to understand the influence of underwater environment on IDTs with different structures. The underwater attenuation of IDT with 2-5 mm wavelength and the underwater attenuation of Lamb (A0 mode) wave on a 4 mm thick titanium alloy plate is obtained through COMSOL software simulation. The experimental verification shows that the simulation results match with the actual situation, which proves that COMSOL software can accurately calculate the acoustic attenuation of surface waves at the solid-liquid interface. At the same time, the underwater attenuation of IDT with different structures is very different, providing important design parameters for the underwater interdigital transducer. In this paper, it is found that the Lamb wave has significant advantages over the Rayleigh wave in the health monitoring of underwater thin plate structures.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China