Your browser doesn't support javascript.
loading
A Prototype for a Passive Resonant Interferometric Fiber Optic Gyroscope with a 3 × 3 Directional Coupler.
Ovchinnikov, Konstantin A; Gilev, Daniil G; Krishtop, Victor V; Volyntsev, Anatoliy B; Maximenko, Vitaliy A; Garkushin, Alexey A; Filatov, Yurii V; Kukaev, Alexander S; Sevryugin, Alexander A; Shalymov, Egor V; Venediktova, Anastasiya V; Venediktov, Vladimir Yu.
Afiliação
  • Ovchinnikov KA; Faculty of Physics, Perm State University, 614068 Perm, Russia.
  • Gilev DG; Perm Scientific-Industrial Instrument Making Company, 614068 Perm, Russia.
  • Krishtop VV; Faculty of Physics, Perm State University, 614068 Perm, Russia.
  • Volyntsev AB; Perm Scientific-Industrial Instrument Making Company, 614068 Perm, Russia.
  • Maximenko VA; Faculty of Physics, Perm State University, 614068 Perm, Russia.
  • Garkushin AA; Perm Scientific-Industrial Instrument Making Company, 614068 Perm, Russia.
  • Filatov YV; Department of General Physics, Perm National Research Polytechnic University, 614990 Perm, Russia.
  • Kukaev AS; Faculty of Physics, Perm State University, 614068 Perm, Russia.
  • Sevryugin AA; Department of General Physics, Perm National Research Polytechnic University, 614990 Perm, Russia.
  • Shalymov EV; Perm Scientific-Industrial Instrument Making Company, 614068 Perm, Russia.
  • Venediktova AV; Department of General Physics, Perm National Research Polytechnic University, 614990 Perm, Russia.
  • Venediktov VY; Laser Measurement and Navigation Systems Department, Electrotechnical University "LETI", 197022 St. Petersburg, Russia.
Sensors (Basel) ; 23(3)2023 Jan 24.
Article em En | MEDLINE | ID: mdl-36772358
ABSTRACT
Reducing the dimensions of optical gyroscopes is a crucial task and resonant fiber optic gyroscopes are promising candidates for its solution. The paper presents a prototype of a miniature resonant interferometric gyroscope of a strategic accuracy class. Due to the use of passive optical elements in this gyroscope, it has a great potential for miniaturization, alongside a low production cost and ease of implementation, since it does not require many feedback loops. The presented prototype shows results on a zero instability of 20°/h and an angle random walk of 0.16°/√h. A theoretical model explaining the nature of the multipath interference of resonant spectra and establishing the relationship between the resonator parameters and the output parameters of the presented prototype is proposed. The results predicted are in agreement with the experimental data. The prototype gyroscope demonstrates a scale factor instability and a change in the average signal level, which is due to the presence of polarization non-reciprocity, occurring due to the induced birefringence in the single-mode fiber of the contour. This problem requires further investigation to be performed.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Federação Russa

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Sensors (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Federação Russa