Strategies to safely rule out pulmonary embolism in COVID-19 outpatients: a multicenter retrospective study.
Eur Radiol
; 33(8): 5540-5548, 2023 Aug.
Article
em En
| MEDLINE
| ID: mdl-36826504
ABSTRACT
OBJECTIVES:
The objective was to define a safe strategy to exclude pulmonary embolism (PE) in COVID-19 outpatients, without performing CT pulmonary angiogram (CTPA).METHODS:
COVID-19 outpatients from 15 university hospitals who underwent a CTPA were retrospectively evaluated. D-Dimers, variables of the revised Geneva and Wells scores, as well as laboratory findings and clinical characteristics related to COVID-19 pneumonia, were collected. CTPA reports were reviewed for the presence of PE and the extent of COVID-19 disease. PE rule-out strategies were based solely on D-Dimer tests using different thresholds, the revised Geneva and Wells scores, and a COVID-19 PE prediction model built on our dataset were compared. The area under the receiver operating characteristics curve (AUC), failure rate, and efficiency were calculated.RESULTS:
In total, 1369 patients were included of whom 124 were PE positive (9.1%). Failure rate and efficiency of D-Dimer > 500 µg/l were 0.9% (95%CI, 0.2-4.8%) and 10.1% (8.5-11.9%), respectively, increasing to 1.0% (0.2-5.3%) and 16.4% (14.4-18.7%), respectively, for an age-adjusted D-Dimer level. D-dimer > 1000 µg/l led to an unacceptable failure rate to 8.1% (4.4-14.5%). The best performances of the revised Geneva and Wells scores were obtained using the age-adjusted D-Dimer level. They had the same failure rate of 1.0% (0.2-5.3%) for efficiency of 16.8% (14.7-19.1%), and 16.9% (14.8-19.2%) respectively. The developed COVID-19 PE prediction model had an AUC of 0.609 (0.594-0.623) with an efficiency of 20.5% (18.4-22.8%) when its failure was set to 0.8%.CONCLUSIONS:
The strategy to safely exclude PE in COVID-19 outpatients should not differ from that used in non-COVID-19 patients. The added value of the COVID-19 PE prediction model is minor. KEY POINTS ⢠D-dimer level remains the most important predictor of pulmonary embolism in COVID-19 patients. ⢠The AUCs of the revised Geneva and Wells scores using an age-adjusted D-dimer threshold were 0.587 (95%CI, 0.572 to 0.603) and 0.588 (95%CI, 0.572 to 0.603). ⢠The AUC of COVID-19-specific strategy to rule out pulmonary embolism ranged from 0.513 (95%CI 0.503 to 0.522) to 0.609 (95%CI 0.594 to 0.623).Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Embolia Pulmonar
/
COVID-19
Tipo de estudo:
Clinical_trials
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Humans
Idioma:
En
Revista:
Eur Radiol
Assunto da revista:
RADIOLOGIA
Ano de publicação:
2023
Tipo de documento:
Article
País de afiliação:
França