Your browser doesn't support javascript.
loading
Comparison of two hybrid sentinel node tracers: indocyanine green (ICG)-99mTc-nanocolloid vs. ICG-99mTc-nanoscan from a nuclear medicine and surgical perspective.
Vreeburg, Manon T A; Azargoshasb, Samaneh; van Willigen, Danny; Molenaar, Tom; van Oosterom, Matthias N; Buckle, Tessa; Slof, Leon J; Klop, Martin; Karakullukcu, Baris; Donswijk, Maarten; van der Poel, Henk G; van Leeuwen, Fijs W B; Brouwer, Oscar R; Rietbergen, Daphne D D.
Afiliação
  • Vreeburg MTA; Department of Urology, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands.
  • Azargoshasb S; Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Hospital, Leiden, The Netherlands.
  • van Willigen D; Department of Urology, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands.
  • Molenaar T; Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Hospital, Leiden, The Netherlands.
  • van Oosterom MN; Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Hospital, Leiden, The Netherlands.
  • Buckle T; Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Hospital, Leiden, The Netherlands.
  • Slof LJ; Radiochemistry Facility, Department of Radiology, Leiden University Medical Hospital, Leiden, The Netherlands.
  • Klop M; Department of Urology, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands.
  • Karakullukcu B; Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Hospital, Leiden, The Netherlands.
  • Donswijk M; Department of Urology, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands.
  • van der Poel HG; Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Hospital, Leiden, The Netherlands.
  • van Leeuwen FWB; Department of Urology, The Netherlands Cancer Institute-Antoni van Leeuwenhoek Hospital, Amsterdam, The Netherlands.
  • Brouwer OR; Interventional Molecular Imaging Laboratory, Department of Radiology, Leiden University Medical Hospital, Leiden, The Netherlands.
  • Rietbergen DDD; Instrumentele zaken ontwikkeling, facilitair bedrijf, Leiden University Medical Centre, Leiden, The Netherlands.
Eur J Nucl Med Mol Imaging ; 50(8): 2282-2291, 2023 07.
Article em En | MEDLINE | ID: mdl-36929210
ABSTRACT

BACKGROUND:

Lymph node (LN) metastasis is a relevant predictor for survival in patients with a.o. penile cancer (PeCa), malignant melanoma. The sentinel node (SN) procedure comprises targeted resection of the first tumour-draining SNs. Here, the hybrid tracer indocyanine green (ICG)-99mTc-nanocolloid has been used for several years to combine optical and nuclear detection. Recently, the resource of the nanocolloid precursor stopped production and the precursor was replaced by a different but chemically comparable colloid, nanoscan. Our aim was to study the performance of ICG-99mTc-nanoscan compared to ICG-99mTc-nanocolloid from a nuclear and surgical perspective.

METHODS:

Twenty-four patients with either PeCa or head-and-neck (H&N) melanoma and scheduled for a SN procedure were included. The initial group (n = 11) received ICG-99mTc-nanocolloid until no longer available; the second group (n = 13) received ICG-99mTc-nanoscan. Tracer uptake was assessed on lymphoscintigraphy and single-photon emission (SPECT). Intraoperatively, SNs were identified using gamma tracing and fluorescence imaging. Ex vivo (back-table) measurements were conducted to quantify the fluorescence emissions. Chemical analysis was performed to compare the ICG assembly on both precursors.

RESULTS:

The mean tracer uptake in the SNs was similar for ICG-99mTc-nanocolloid (2.2 ± 4.3%ID) and ICG-99mTc-nanoscan (1.8 ± 2.6%ID; p = 0.68). 3 SNs (interquartile range (IQR) 3-4) were detected on lymphoscintigraphy in PeCa patients receiving ICG-99mTc-nanoscan compared to 2 SNs (IQR 2-3) in PeCa patients receiving ICG-99mTc-nanocolloid (p = 0.045), no differences were observed in H&N patients. Back-table measurements of resected SNs revealed a lower total fluorescence intensity in the ICG-99mTc-nanoscan group (24*109 arbitrary units (A.U) IQR 1.6*109-14*109 in the ICG-99mTc-nanocolloid group versus 4.6*109 A.U. IQR 2.4*109-42*109 in the ICG-99mTc-nanoscan group, p = 0.0054). This was consistent with a larger degree of "stacked" ICG observed in the nanoscan formulation. No tracer-related adverse events were reported.

CONCLUSIONS:

Based on this retrospective analysis, we can conclude that ICG-99mTc-nanoscan has similar capacity for SN identification as ICG-99mTc-nanocolloid and can safely be implemented in SN procedures.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Penianas / Linfonodo Sentinela / Melanoma / Medicina Nuclear Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Humans / Male Idioma: En Revista: Eur J Nucl Med Mol Imaging Assunto da revista: MEDICINA NUCLEAR Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Penianas / Linfonodo Sentinela / Melanoma / Medicina Nuclear Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Humans / Male Idioma: En Revista: Eur J Nucl Med Mol Imaging Assunto da revista: MEDICINA NUCLEAR Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Holanda