Your browser doesn't support javascript.
loading
Multimodal Remote Home Monitoring of Lung Transplant Recipients during COVID-19 Vaccinations: Usability Pilot Study of the COVIDA Desk Incorporating Wearable Devices.
Schuurmans, Macé M; Muszynski, Michal; Li, Xiang; Marcinkevics, Ricards; Zimmerli, Lukas; Monserrat Lopez, Diego; Michel, Bruno; Weiss, Jonas; Hage, René; Roeder, Maurice; Vogt, Julia E; Brunschwiler, Thomas.
Afiliação
  • Schuurmans MM; Division of Pulmonology, University Hospital Zurich, 8091 Zurich, Switzerland.
  • Muszynski M; Faculty of Medicine, University of Zurich, 8032 Zurich, Switzerland.
  • Li X; IBM Research Europe, 8803 Rüschlikon, Switzerland.
  • Marcinkevics R; Department of Mathematics, ETH Zurich, 8092 Zurich, Switzerland.
  • Zimmerli L; Department of Computer Science, ETH Zurich, 8092 Zurich, Switzerland.
  • Monserrat Lopez D; Department of Computer Science, ETH Zurich, 8092 Zurich, Switzerland.
  • Michel B; IBM Research Europe, 8803 Rüschlikon, Switzerland.
  • Weiss J; IBM Research Europe, 8803 Rüschlikon, Switzerland.
  • Hage R; Department of Biosystems Science and Engineering, ETH Zurich, 4058 Basel, Switzerland.
  • Roeder M; IBM Research Europe, 8803 Rüschlikon, Switzerland.
  • Vogt JE; IBM Research Europe, 8803 Rüschlikon, Switzerland.
  • Brunschwiler T; Division of Pulmonology, University Hospital Zurich, 8091 Zurich, Switzerland.
Medicina (Kaunas) ; 59(3)2023 Mar 20.
Article em En | MEDLINE | ID: mdl-36984618
ABSTRACT
Background and

Objectives:

Remote patient monitoring (RPM) of vital signs and symptoms for lung transplant recipients (LTRs) has become increasingly relevant in many situations. Nevertheless, RPM research integrating multisensory home monitoring in LTRs is scarce. We developed a novel multisensory home monitoring device and tested it in the context of COVID-19 vaccinations. We hypothesize that multisensory RPM and smartphone-based questionnaire feedback on signs and symptoms will be well accepted among LTRs. To assess the usability and acceptability of a remote monitoring system consisting of wearable devices, including home spirometry and a smartphone-based questionnaire application for symptom and vital sign monitoring using wearable devices, during the first and second SARS-CoV-2 vaccination. Materials and

Methods:

Observational usability pilot study for six weeks of home monitoring with the COVIDA Desk for LTRs. During the first week after the vaccination, intensive monitoring was performed by recording data on physical activity, spirometry, temperature, pulse oximetry and self-reported symptoms, signs and additional measurements. During the subsequent days, the number of monitoring assessments was reduced. LTRs reported on their perceptions of the usability of the monitoring device through a purpose-designed questionnaire.

Results:

Ten LTRs planning to receive the first COVID-19 vaccinations were recruited. For the intensive monitoring study phase, LTRs recorded symptoms, signs and additional measurements. The most frequent adverse events reported were local pain, fatigue, sleep disturbance and headache. The duration of these symptoms was 5-8 days post-vaccination. Adherence to the main monitoring devices was high. LTRs rated usability as high. The majority were willing to continue monitoring.

Conclusions:

The COVIDA Desk showed favorable technical performance and was well accepted by the LTRs during the vaccination phase of the pandemic. The feasibility of the RPM system deployment was proven by the rapid recruitment uptake, technical performance (i.e., low number of errors), favorable user experience questionnaires and detailed individual user feedback.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transplantados / Dispositivos Eletrônicos Vestíveis / Vacinas contra COVID-19 / COVID-19 Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Medicina (Kaunas) Assunto da revista: MEDICINA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Transplantados / Dispositivos Eletrônicos Vestíveis / Vacinas contra COVID-19 / COVID-19 Tipo de estudo: Observational_studies Limite: Humans Idioma: En Revista: Medicina (Kaunas) Assunto da revista: MEDICINA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Suíça