Your browser doesn't support javascript.
loading
Description and validation of an equilibrium dialysis ID-LC-MS/MS candidate reference measurement procedure for free thyroxine in human serum.
Jansen, Heleen I; van der Steen, Rob; Brandt, André; Olthaar, André J; Vesper, Hubert W; Shimizu, Eri; Heijboer, Annemieke C; Van Uytfanghe, Katleen; van Herwaarden, Antonius E.
Afiliação
  • Jansen HI; Department of Clinical Chemistry, Endocrine Laboratory, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
  • van der Steen R; Department of Clinical Chemistry, Endocrine Laboratory, Amsterdam UMC Location University of Amsterdam, Amsterdam, The Netherlands.
  • Brandt A; Amsterdam Gastroenterology Endocrinology & Metabolism, Amsterdam, The Netherlands.
  • Olthaar AJ; Department of Laboratory Medicine, Radboud University Medical Center, Nijmegen, The Netherlands.
  • Vesper HW; Department of Laboratory Medicine, Radboud University Medical Center, Nijmegen, The Netherlands.
  • Shimizu E; Department of Laboratory Medicine, Radboud University Medical Center, Nijmegen, The Netherlands.
  • Heijboer AC; Division of Laboratory Sciences, Centers for Disease Control and Prevention, Atlanta, GA, USA.
  • Van Uytfanghe K; Reference Material Institute for Clinical Chemistry Standards, Yokohama, Kanagawa, Japan.
  • van Herwaarden AE; Department of Clinical Chemistry, Endocrine Laboratory, Amsterdam UMC Location Vrije Universiteit Amsterdam, Amsterdam, The Netherlands.
Clin Chem Lab Med ; 61(9): 1605-1611, 2023 08 28.
Article em En | MEDLINE | ID: mdl-36994743
OBJECTIVES: Free thyroxine (FT4) in serum is routinely measured in clinical practice to diagnose and monitor thyroid disease. Due to its concentration in picomolar range and the delicate equilibrium of free and protein-bound T4, accurate measurement is challenging. As a consequence, large inter-method differences in FT4 results exists. Optimal method design and standardization of the FT4 measurement is therefore necessary. The IFCC Working Group for Standardization of Thyroid Function Tests proposed a reference system with a conventional reference measurement procedure (cRMP) for FT4 in serum. In this study, we describe our FT4 candidate cRMP and its validation in clinical samples. METHODS: This candidate cRMP is based on equilibrium dialysis (ED) combined with determination of T4 with an isotope-dilution liquid chromatography tandem mass-spectrometry (ID-LC-MS/MS) procedure and was developed according to the endorsed conventions. Its accuracy, reliability, and comparability was investigated using human sera. RESULTS: It was shown that the candidate cRMP adhered to the conventions and its accuracy, precision, and robustness were adequate in serum of healthy volunteers. CONCLUSIONS: Our candidate cRMP measures FT4 accurately and performs well in serum matrix.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tiroxina / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tiroxina / Espectrometria de Massas em Tandem Limite: Humans Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Holanda