Your browser doesn't support javascript.
loading
Fast-release kinetics of a pH-responsive polymer detected by dynamic contact angles.
Li, Xiaomei; Auepattana-Aumrung, Krisada; Butt, Hans-Jürgen; Crespy, Daniel; Berger, Rüdiger.
Afiliação
  • Li X; Max Planck Institute for Polymer Research, Mainz, Germany.
  • Auepattana-Aumrung K; Department of Materials Science and Engineering, School of Molecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong 21210, Thailand.
  • Butt HJ; Max Planck Institute for Polymer Research, Mainz, Germany.
  • Crespy D; Department of Materials Science and Engineering, School of Molecular Science and Engineering, Vidyasirimedhi Institute of Science and Technology (VISTEC), Rayong 21210, Thailand.
  • Berger R; Max Planck Institute for Polymer Research, Mainz, Germany.
J Chem Phys ; 158(14): 144901, 2023 Apr 14.
Article em En | MEDLINE | ID: mdl-37061469
Polymers conjugated with active agents have applications in biomedicine, anticorrosion, and smart agriculture. When the active agent is used as a drug, corrosion inhibitor, or pesticide, it can be released upon a specific stimulus. The efficiency and the sustainability of active agents are determined by the released kinetics. In this work, we study the fast-release kinetics of 8-hydroxyquinoline (8HQ) from a pH-responsive, random copolymer of methyl methacrylate and 8-quinolinyl-sulfide-ethyl acrylate [P(MMA-co-HQSEA)] by hydrolysis of the ß-thiopropionate groups. We used contact angle measurements of sliding drops as an elegant way to characterize the release kinetics. Based on the results gained from 1H nuclear magnetic resonance measurement, fluorescent intensity measurement, and velocity-dependent contact angle measurement, we found that both the hydrolysis rate and polymer conformation affect the release kinetics of 8HQ from a P(MMA-co-HQSEA) film. Polymer chains collapse and further suppress the release from the inner layer in acidic conditions, while polymer chains in a stretched condition further facilitate the release from the inner layer. As a result, the cumulative release rate of 8HQ is higher in the basic condition than in the acidic condition.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Chem Phys Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Chem Phys Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Alemanha