Your browser doesn't support javascript.
loading
Measurement of an evaporation coefficient in tissue sections as a correction factor for 10B determination.
Espector, Natalia; Portu, Agustina Mariana; Espain, María Sol; Leyva, Gabriela; Saint Martin, Gisela.
Afiliação
  • Espector N; Departamento de Radiobiología, Comisión Nacional de Energía Atómica (CNEA), Av. General Paz 1499, San Martin, B1650KNA, Buenos Aires, Argentina.
  • Portu AM; Departamento de Radiobiología, Comisión Nacional de Energía Atómica (CNEA), Av. General Paz 1499, San Martin, B1650KNA, Buenos Aires, Argentina. agustina.portu@gmail.com.
  • Espain MS; Comisión Nacional de Investigaciones Científicas y Técnicas (CONICET), Capital Federal, Buenos Aires, Argentina. agustina.portu@gmail.com.
  • Leyva G; Departamento de Radiobiología, Comisión Nacional de Energía Atómica (CNEA), Av. General Paz 1499, San Martin, B1650KNA, Buenos Aires, Argentina.
  • Saint Martin G; Comisión Nacional de Investigaciones Científicas y Técnicas (CONICET), Capital Federal, Buenos Aires, Argentina.
Histochem Cell Biol ; 160(1): 3-10, 2023 Jul.
Article em En | MEDLINE | ID: mdl-37126141
ABSTRACT
Boron neutron capture therapy (BNCT) is a cancer treatment option that combines preferential uptake of a boron compound in tumors and irradiation with thermal neutrons. For treatment planning, the boron concentration in different tissues must be considered. Neutron autoradiography using nuclear track detectors (NTD) can be applied to study both the concentration and microdistribution of boron in tissue samples. Histological sections are obtained from frozen tissue by cryosectioning. When the samples reach room temperature, they undergo an evaporation process, which leads to an increase in the boron concentration. To take this effect into account, certain correction factors (evaporation coefficients, CEv) must be applied. With this aim, a protocol was established to register and analyze mass variation of tissue sections, measured with a semimicro scale. Values of ambient temperature, pressure, and humidity were simultaneously recorded. Reproducible results of evaporation curves and CEv values were obtained for different tissue samples, which allowed the systematization of the procedure. This study could contribute to a more precise determination of boron concentration in tissue samples through the neutron autoradiography technique, which is of great relevance to make dosimetric calculations in BNCT.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Terapia por Captura de Nêutron de Boro / Neoplasias Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: Histochem Cell Biol Assunto da revista: CITOLOGIA / HISTOCITOQUIMICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Argentina

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Terapia por Captura de Nêutron de Boro / Neoplasias Tipo de estudo: Guideline Limite: Humans Idioma: En Revista: Histochem Cell Biol Assunto da revista: CITOLOGIA / HISTOCITOQUIMICA Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Argentina