Your browser doesn't support javascript.
loading
Augmentation Uretero-enterocystoplasty Is an Effective Procedure in Protecting the Upper Urinary Tract Without Accelerating Deterioration of Renal Function.
Wang, Xuesheng; Zhou, Zhonghan; Zhang, Fan; Li, Xing; Liao, Limin.
Afiliação
  • Wang X; Department of Urology, China Rehabilitation Research Center, School of Rehabilitation of Capital Medical University, Beijing, China.
  • Zhou Z; University of Health and Rehabilitation Sciences, Qingdao, China.
  • Zhang F; University of Health and Rehabilitation Sciences, Qingdao, China.
  • Li X; Cheeloo College of Medicine, Shandong University, Jinan, China.
  • Liao L; Department of Urology, China Rehabilitation Research Center, School of Rehabilitation of Capital Medical University, Beijing, China.
Eur Urol Open Sci ; 51: 62-69, 2023 May.
Article em En | MEDLINE | ID: mdl-37187718
ABSTRACT

Background:

Augmentation uretero-enterocystoplasty (AUEC) provides a low-pressure urinary storage capsule that can preserve renal function in patients with lower urinary tract dysfunction for whom conservative treatments have failed.

Objective:

To summarize the effectiveness and safety of augmentation uretero-enterocystoplasty (AUEC) and evaluate whether it aggravates renal function deterioration in patients with renal insufficiency. Design setting and

participants:

This was a retrospective cohort study of patients who underwent AUEC from 2006 to 2021. Patients were grouped according to whether they had normal renal function (NRF) or renal dysfunction (serum creatinine >1.5 mg/dl). Outcome measurements and statistical

analysis:

Follow-up of upper and lower urinary tract function was assessed via review of clinical records, urodynamic data, and laboratory results. Results and

limitations:

We included 156 patients in the NRF group and 68 in the renal dysfunction group. We confirmed that urodynamic parameters and upper urinary tract dilation were significantly improved for patients after AUEC. Serum creatinine declined during the first 10 mo in both groups and remained stable thereafter. The reduction in serum creatine was significantly greater in the renal dysfunction group than in the NRF group in the first 10 mo (difference in reduction 4.19 units; p < 0.05). A multivariable regression model showed that baseline renal dysfunction was not a significant risk factor for deterioration of renal function in patients who had undergone AUEC (odds ratio 2.15; p = 0.11). The main limitations are selection bias because of the retrospective design, loss to follow-up, and missing data.

Conclusions:

AUEC is a safe and effective procedure to protect the upper urinary tract and will not hasten deterioration of renal function in patients with lower urinary tract dysfunction. In addition, AUEC improved and stabilized residual renal function in patients with renal insufficiency, which is important in preparation for renal transplantation. Patient

summary:

Bladder dysfunction is usually treated with medication or Botox injections. If these treatments fail, surgery to increase the bladder size using a portion of the patient's intestine is a possible option. Our study shows that this procedure was safe and feasible and improved bladder function. It did not lead to a further decrease in function in patients who already had impaired kidney function.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Eur Urol Open Sci Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Eur Urol Open Sci Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China