Your browser doesn't support javascript.
loading
Assessment of efficacy and safety of advanced endoscopic irreversible electroporation catheter in the esophagus.
Jeon, Han Jo; Choi, Hyuk Soon; Lee, Jae Min; Kim, Eun Sun; Keum, Bora; Jeen, Yoon Tae; Lee, Hong Sik; Chun, Hoon Jai; Jeong, Seung; Kim, Hong Bae; Kim, Jong Hyuk.
Afiliação
  • Jeon HJ; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
  • Choi HS; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea. mdkorea@gmail.com.
  • Lee JM; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
  • Kim ES; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
  • Keum B; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
  • Jeen YT; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
  • Lee HS; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
  • Chun HJ; Division of Gastroenterology and Hepatology, Department of Internal Medicine, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
  • Jeong S; Department of Biosystems and Biomaterials Science and Engineering, Seoul National University, Seoul, Republic of Korea.
  • Kim HB; Department of Biosystems and Biomaterials Science and Engineering, Seoul National University, Seoul, Republic of Korea.
  • Kim JH; Department of Veterinary Clinical Sciences, College of Veterinary Medicine, University of Minnesota, St. Paul, MN, USA.
Sci Rep ; 13(1): 7917, 2023 05 16.
Article em En | MEDLINE | ID: mdl-37193702
ABSTRACT
Nonthermal irreversible electroporation (NTIRE) is emerging as a promising tissue ablation technique. However, maintaining irreversible electroporation (IRE) electrodes against displacement during strong esophageal spasms remains an obstacle. The present study aimed to evaluate the efficacy and safety of newly designed balloon-type endoscopic IRE catheters. Six pigs were randomly allocated to each catheter group, and each pig was subjected to four ablations at alternating voltages of 1500 V and 2000 V. Esophagogastroscopy was performed during the IRE. The ability of balloon-type catheters to execute complete IRE with 40 pulses was assessed. The success rate was higher for the balloon-type catheter than that for the basket-type (12/12 [100%] vs. 2/12 [16.7%], p < 0.001). Following gross inspection and histologic analysis of the 1500-V vs. 2000-V balloon-type catheter revealed a larger mucosal damage area (105.3 mm2 vs. 140.8 mm2, p = 0.004) and greater damage depth (476 µm vs. 900 µm, p = 0.02). Histopathology of the ablated tissue revealed separated epithelium, inflamed lamina propria, congested muscularis mucosa, necrotized submucosa, and disorganized muscularis propria. Balloon-type catheters demonstrated efficacy, achieving full electrical pulse sequences under NTIRE conditions, and a safe histological profile below 2000 V (1274 V/cm). Optimal electrical conditions and electrode arrays pose ongoing challenges.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ablação por Cateter / Esôfago Limite: Animals Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ablação por Cateter / Esôfago Limite: Animals Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article