Your browser doesn't support javascript.
loading
Environmental noise reduction for tunable resistive pulse sensing of extracellular vesicles.
Ejjigu, Nega; Abdelgadir, Khalid; Flaten, Zachariah; Hoff, Cameron; Li, Chen-Zhong; Sun, Dali.
Afiliação
  • Ejjigu N; Biomedical Engineering Program, North Dakota State University, Engineering Administration, Room 203, 1401 Centennial Blvd, Fargo, ND 58102, USA.
  • Abdelgadir K; Department of Electrical and Computer Engineering, North Dakota State University, 1411 Centennial Blvd., 101 S, Fargo, ND 58102, USA.
  • Flaten Z; Biomedical Engineering Program, North Dakota State University, Engineering Administration, Room 203, 1401 Centennial Blvd, Fargo, ND 58102, USA.
  • Hoff C; Department of Electrical and Computer Engineering, North Dakota State University, 1411 Centennial Blvd., 101 S, Fargo, ND 58102, USA.
  • Li CZ; Center for Cellular and Molecular Diagnostics, Department of Biochemistry and Molecular Biology, Department of Biomedical Engineering, Tulane University, LA 70112, USA.
  • Sun D; Biomedical Engineering Program, North Dakota State University, Engineering Administration, Room 203, 1401 Centennial Blvd, Fargo, ND 58102, USA.
Sens Actuators A Phys ; 3462022 Oct 16.
Article em En | MEDLINE | ID: mdl-37273787
ABSTRACT
Extracellular vesicles (EVs) bearing biomolecules from parental cells can represent a novel source of disease biomarkers and are under intensive study for their clinical potential. Tunable resistive pulse sensing (TRPS) quantifies the magnitude of a small ionic resistive pulse current to determine the size, concentration, and zeta potential of EVs. Environmental noise is a common limiting factor that affects the precision of sensing devices. TRPS is particularly vulnerable to environmental noise, including both mechanical and electrical. The upper detection limit of the TRPS relies on the physical size of the elastomeric tunable nanopore. The lower limit relies on the electrical signal-to-noise ratio. Guided by simulation, we designed an external device to suppress environmental noise for TRPS measurement. Both mechanical and electrical environmental noise reductions were observed after using the shield. The study also validated the noise reduction function of the shield by quantifying EVs from different cell origins. Detection of EVs smaller than 200 nm was improved by using the shield; which was reported challenging for conventional quantification methods. The study highlighted a feasible approach to solve environmental noise challenges for TRPS based EV quantification.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sens Actuators A Phys Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sens Actuators A Phys Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Estados Unidos