Your browser doesn't support javascript.
loading
Accuracy of Four Different CT Perfusion Thresholds for Ischemic Core Volume and Location Estimation Using IntelliSpace Portal.
Koopman, Miou S; Hoving, Jan W; Tolhuisen, Manon L; Jin, Peng; Thiele, Frank O; Bremer-van der Heiden, Linda; van Voorst, Henk; Berkhemer, Olvert A; Coutinho, Jonathan M; Beenen, Ludo F M; Marquering, Henk A; Emmer, Bart J; Majoie, Charles B L M.
Afiliação
  • Koopman MS; Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands.
  • Hoving JW; Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands.
  • Tolhuisen ML; Department of Biomedical Engineering and Physics, Amsterdam UMC, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands.
  • Jin P; Philips Medical Systems, Philips Healthcare, 5684 PC Best, The Netherlands.
  • Thiele FO; Philips GmbH Innovative Technologies, 52074 Aachen, Germany.
  • Bremer-van der Heiden L; Philips Medical Systems, Philips Healthcare, 5684 PC Best, The Netherlands.
  • van Voorst H; Department of Biomedical Engineering and Physics, Amsterdam UMC, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands.
  • Berkhemer OA; Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands.
  • Coutinho JM; Department of Neurology, Amsterdam UMC, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands.
  • Beenen LFM; Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands.
  • Marquering HA; Department of Biomedical Engineering and Physics, Amsterdam UMC, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands.
  • Emmer BJ; Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands.
  • Majoie CBLM; Department of Radiology and Nuclear Medicine, Amsterdam UMC, University of Amsterdam, 1105 AZ Amsterdam, The Netherlands.
J Cardiovasc Dev Dis ; 10(6)2023 May 30.
Article em En | MEDLINE | ID: mdl-37367404
Computed tomography perfusion (CTP) is frequently used in the triage of ischemic stroke patients for endovascular thrombectomy (EVT). We aimed to quantify the volumetric and spatial agreement of the CTP ischemic core estimated with different thresholds and follow-up MRI infarct volume on diffusion-weighted imaging (DWI). Patients treated with EVT between November 2017 and September 2020 with available baseline CTP and follow-up DWI were included. Data were processed with Philips IntelliSpace Portal using four different thresholds. Follow-up infarct volume was segmented on DWI. In 55 patients, the median DWI volume was 10 mL, and median estimated CTP ischemic core volumes ranged from 10-42 mL. In patients with complete reperfusion, the intraclass correlation coefficient (ICC) showed moderate-good volumetric agreement (range 0.55-0.76). A poor agreement was found for all methods in patients with successful reperfusion (ICC range 0.36-0.45). Spatial agreement (median Dice) was low for all four methods (range 0.17-0.19). Severe core overestimation was most frequently (27%) seen in Method 3 and patients with carotid-T occlusion. Our study shows moderate-good volumetric agreement between ischemic core estimates for four different thresholds and subsequent infarct volume on DWI in EVT-treated patients with complete reperfusion. The spatial agreement was similar to other commercially available software packages.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Cardiovasc Dev Dis Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Cardiovasc Dev Dis Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Holanda