Sensitivity-enhanced Fabry-Perot interferometric fiber-optic microphone using hollow cantilever.
Opt Express ; 31(13): 21796-21805, 2023 Jun 19.
Article em En | MEDLINE | ID: mdl-37381268
ABSTRACT
Transducer components are crucial in optimizing the sensitivity of microphones. Cantilever structure is commonly used as a structural optimization technique. Here, we present a novel Fabry-Perot (F-P) interferometric fiber-optic microphone (FOM) using a hollow cantilever structure. The proposed hollow cantilever aims to reduce the effective mass and spring constant of the cantilever, thereby enhancing the sensitivity of the FOM. Experimental results demonstrate that the proposed structure outperforms the original cantilever design in terms of sensitivity. The sensitivity and minimum detectable acoustic pressure level (MDP) can reach 91.40 mV/Pa and 6.20 µPa/Hz at 1.7 kHz, respectively. Notably, the hollow cantilever provides an optimization framework for highly sensitive FOMs.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Opt Express Assunto da revista: OFTALMOLOGIA Ano de publicação: 2023 Tipo de documento: Article