Your browser doesn't support javascript.
loading
The financial burden associated with endovascular repair of thoracoabdominal and pararenal aortic aneurysms using physician-modified fenestrated-branched endografts.
Ilyas, Sadia; Stone, David H; Powell, Richard J; Ponukumati, Aravind S; Kuwayama, David P; Goodney, Philip P; Columbo, Jesse A; Suckow, Bjoern D.
Afiliação
  • Ilyas S; Department of Vascular Surgery, Medstar Washington Hospital Center, Washington, DC.
  • Stone DH; Section of Vascular Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH.
  • Powell RJ; Section of Vascular Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH.
  • Ponukumati AS; Section of Vascular Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH.
  • Kuwayama DP; Section of Vascular Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH.
  • Goodney PP; Section of Vascular Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH.
  • Columbo JA; Section of Vascular Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH.
  • Suckow BD; Section of Vascular Surgery, Dartmouth-Hitchcock Medical Center, Lebanon, NH. Electronic address: Bjoern.D.Suckow@hitchcock.org.
J Vasc Surg ; 78(6): 1369-1375, 2023 12.
Article em En | MEDLINE | ID: mdl-37390850
ABSTRACT
OBJECTIVE/

BACKGROUND:

Endovascular thoracoabdominal and pararenal aortic aneurysm repair is more complex and requires more devices than infrarenal aneurysm repair. It is unclear if current reimbursement covers the cost of delivering this more advanced form of vascular care. The objective of this study was to evaluate the economics of fenestrated-branched (FB-EVAR) physician-modified endograft (PMEG) repairs.

METHODS:

We obtained technical and professional cost and revenue data for four consecutive fiscal years (July 1, 2017, to June 30, 2021) at our quaternary referral institution. Inclusion criteria were patients who underwent PMEG FB-EVAR in a uniform fashion by a single surgeon for thoracoabdominal/pararenal aortic aneurysms. Patients in industry-sponsored clinical trials or receiving Cook Zenith Fenestrated grafts were excluded. Financial data were analyzed for the index operation. Technical costs were divided into direct costs that included devices and billable supplies and indirect costs including overhead.

RESULTS:

62 patients (79% male, mean age 74 years, 66% thoracoabdominal aneurysms) met inclusion criteria. The mean aneurysm size was 6.0 cm, the mean total operating time was 219 minutes, and the median hospital length of stay was 2 days. PMEGs were created with a mean number of 3.7 fenestrations, using a mean of 8.6 implantable devices per case. The average technical cost per case was $71,198, and the average technical reimbursement was $57,642, providing a net negative technical margin of $13,556 per case. Of this cohort, 31 patients (50%) were insured by Medicare remunerated under diagnosis-related group code 268/269. Their respective average technical reimbursement was $41,293, with a mean negative margin of $22,989 per case, with similar findings for professional costs. The primary driver of technical cost was implantable devices, accounting for 77% of total technical cost per case over the study period. The total operating margin, including technical and professional cost and revenue, for the cohort during the study period was negative $1,560,422.

CONCLUSIONS:

PMEG FB-EVAR for pararenal/thoracoabdominal aortic aneurysms produces a substantially negative operating margin for the index operation driven largely by device costs. Device cost alone already exceeds total technical revenue and presents an opportunity for cost reduction. In addition, increased reimbursement for FB-EVAR, especially among Medicare beneficiaries, will be important to facilitate patient access to such innovative technology.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos Endovasculares / Cirurgiões / Aneurisma da Aorta Toracoabdominal Tipo de estudo: Health_economic_evaluation / Risk_factors_studies Limite: Aged / Female / Humans / Male País/Região como assunto: America do norte Idioma: En Revista: J Vasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos Endovasculares / Cirurgiões / Aneurisma da Aorta Toracoabdominal Tipo de estudo: Health_economic_evaluation / Risk_factors_studies Limite: Aged / Female / Humans / Male País/Região como assunto: America do norte Idioma: En Revista: J Vasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2023 Tipo de documento: Article