Your browser doesn't support javascript.
loading
Development of an economical method to synthesize O-(2-[18 F]fluoroethyl)-L-tyrosine (18 FFET).
Kumar, Aishwarya; Joshi, Raman Kumar; Thakur, Riptee; Kumar, Dinesh; Nagaraj, Chandana; Kumar, Pardeep.
Afiliação
  • Kumar A; Department of Neuroimaging and Interventional Radiology (NI&IR), National Institute of Mental Health & Neurosciences (NIMHANS), Bengaluru, Karnataka, India.
  • Joshi RK; Department of Neuroimaging and Interventional Radiology (NI&IR), National Institute of Mental Health & Neurosciences (NIMHANS), Bengaluru, Karnataka, India.
  • Thakur R; Department of Neuroimaging and Interventional Radiology (NI&IR), National Institute of Mental Health & Neurosciences (NIMHANS), Bengaluru, Karnataka, India.
  • Kumar D; Department of Neuroimaging and Interventional Radiology (NI&IR), National Institute of Mental Health & Neurosciences (NIMHANS), Bengaluru, Karnataka, India.
  • Nagaraj C; Department of Neuroimaging and Interventional Radiology (NI&IR), National Institute of Mental Health & Neurosciences (NIMHANS), Bengaluru, Karnataka, India.
  • Kumar P; Department of Neuroimaging and Interventional Radiology (NI&IR), National Institute of Mental Health & Neurosciences (NIMHANS), Bengaluru, Karnataka, India.
J Labelled Comp Radiopharm ; 66(11): 345-352, 2023 09.
Article em En | MEDLINE | ID: mdl-37408511
ABSTRACT
Positron emission tomography (PET) using O-(2-[18 F]fluoroethyl)-L-tyrosine ([18 F]FET) has shown great success in differentiating tumor recurrence from necrosis. In this study, we are reporting the experience of synthesis [18 F]FET by varying the concentration of TET precursor in different chemistry modules. TET precursor (2-10 mg) was used for the synthesis of [18 F]FET in an automated (MX Tracerlab) module (n = 6) and semiautomated (FX2N Tracerlab) module (n = 19). The quality control was performed for all the preparations. For human imaging, 220 ± 50 MBq of [18 F]FET was briefly injected into the patient to acquire PET-MR images. The radiochemical purity was greater than 95% for the final product in both modules. The decay corrected average yield was 10.7 ± 4.7% (10 mg, n = 3) and 8.2 ± 2.6% (2 mg, n = 3) with automated chemistry module and 36.7 ± 7.3% (8-10 mg, n = 12), 26.4 ± 3.1% (5-7 mg, n = 4), and 35.1 ± 3.8% (2-4 mg, n = 3) with semiautomated chemistry modules. The PET imaging showed uptake at the lesion site (SUVmax = 7.5 ± 2.6) and concordance with the MR image. The [18 F]FET was produced with a higher radiochemical yield with 2.0 mg of the precursor with substantial yield and is suitable for brain tumor imaging.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tirosina / Neoplasias Encefálicas Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Revista: J Labelled Comp Radiopharm Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tirosina / Neoplasias Encefálicas Tipo de estudo: Health_economic_evaluation Limite: Humans Idioma: En Revista: J Labelled Comp Radiopharm Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia