Your browser doesn't support javascript.
loading
Monitoring Disassembly and Cargo Release of Phase-Separated Peptide Coacervates with Native Mass Spectrometry.
Cerrato, Carmine P; Leppert, Axel; Sun, Yue; Lane, David P; Arsenian-Henriksson, Marie; Miserez, Ali; Landreh, Michael.
Afiliação
  • Cerrato CP; Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet - Biomedicum, Solnavägen 9, 17165 Solna, Sweden.
  • Leppert A; Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet - Biomedicum, Solnavägen 9, 17165 Solna, Sweden.
  • Sun Y; Biological and Biomimetic Material Laboratory (BBML), Center for Sustainable Materials (SusMat), School of Materials Science and Engineering, Nanyang Technological University (NTU), Singapore, Singapore 637553.
  • Lane DP; Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet - Biomedicum, Solnavägen 9, 17165 Solna, Sweden.
  • Arsenian-Henriksson M; Department of Microbiology, Tumor and Cell Biology, Karolinska Institutet - Biomedicum, Solnavägen 9, 17165 Solna, Sweden.
  • Miserez A; Biological and Biomimetic Material Laboratory (BBML), Center for Sustainable Materials (SusMat), School of Materials Science and Engineering, Nanyang Technological University (NTU), Singapore, Singapore 637553.
  • Landreh M; School of Biological Sciences, Nanyang Technological University (NTU), Singapore, Singapore 637553.
Anal Chem ; 95(29): 10869-10872, 2023 07 25.
Article em En | MEDLINE | ID: mdl-37439740
ABSTRACT
Engineering liquid-liquid phase separation (LLPS) of proteins and peptides holds great promise for the development of therapeutic carriers with intracellular delivery capability but requires accurate determination of their assembly properties in vitro, usually with fluorescently labeled cargo. Here, we use mass spectrometry (MS) to investigate redox-sensitive coacervate microdroplets (the dense phase formed during LLPS) assembled from a short His- and Tyr-rich peptide. We can monitor the enrichment of a reduced peptide in dilute phase as the microdroplets dissolve triggered by their redox-sensitive side chain, thus providing a quantitative readout for disassembly. Furthermore, MS can detect the release of a short peptide from coacervates under reducing conditions. In summary, with MS, we can monitor the disassembly and cargo release of engineered coacervates used as therapeutic carriers without the need for additional labels.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos / Proteínas Idioma: En Revista: Anal Chem Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Suécia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Peptídeos / Proteínas Idioma: En Revista: Anal Chem Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Suécia