Your browser doesn't support javascript.
loading
Myocardial Blood Flow Determination From Contrast-Free Magnetic Resonance Imaging Quantification of Coronary Sinus Flow.
Tingsgaard, Jakob Koefoed; Sørensen, Martin Heyn; Bojer, Annemie Stege; Anderson, Robert H; Broadbent, David Andrew; Plein, Sven; Gaede, Peter; Madsen, Per Lav.
Afiliação
  • Tingsgaard JK; Department of Cardiology, Copenhagen University Hospital, Copenhagen, Denmark.
  • Sørensen MH; Department of Internal Medicine, Slagelse-Naestved Hospital, Denmark.
  • Bojer AS; Department of Internal Medicine, Slagelse-Naestved Hospital, Denmark.
  • Anderson RH; Institute of Genetic Medicine, Newcastle University, UK.
  • Broadbent DA; Department of Medical Physics and Engineering, Leeds Teaching Hospitals, Leeds, UK.
  • Plein S; Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.
  • Gaede P; Leeds Institute of Cardiovascular and Metabolic Medicine, University of Leeds, Leeds, UK.
  • Madsen PL; Department of Internal Medicine, Slagelse-Naestved Hospital, Denmark.
J Magn Reson Imaging ; 59(4): 1258-1266, 2024 Apr.
Article em En | MEDLINE | ID: mdl-37491887
BACKGROUND: Determination of myocardial blood flow (MBF) with MRI is usually performed with dynamic contrast enhanced imaging (MBFDCE ). MBF can also be determined from coronary sinus blood flow (MBFCS ), which has the advantage of being a noncontrast technique. However, comparative studies of MBFDCE and MBFCS in large cohorts are lacking. PURPOSE: To compare MBFCS and MBFDCE in a large cohort. STUDY TYPE: Prospective, sequence-comparison study. POPULATION: 147 patients with type 2 diabetes mellitus (age: 56+/-12 years; 106 male; diabetes duration: 12.9+/-8.1 years), and 25 age-matched controls. FIELD STRENGTH/SEQUENCES: 1.5 Tesla scanner. Saturation recovery sequence for MBFDCE vs. phase-contrast gradient-echo pulse sequence (free-breathing) for MBFCS . ASSESSMENT: MBFDCE and MBFCS were determined at rest and during coronary dilatation achieved by administration of adenosine at 140 µg/kg/min. Myocardial perfusion reserve (MPR) was calculated as the stress/rest ratio of MBF values. Coronary sinus flow was determined twice in the same imaging session for repeatability assessment. STATISTICAL TESTS: Agreement between MBFDCE and MBFCS was assessed with Bland and Altman's technique. Repeatability was determined from single-rater random intraclass and repeatability coefficients. RESULTS: Rest and stress flows, including both MBFDCE and MBFCS values, ranged from 33 to 146 mL/min/100 g and 92 to 501 mL/min/100 g, respectively. Intraclass and repeatability coefficients for MBFCS were 0.95 (CI 0.90; 0.95) and 5 mL/min/100 g. In Bland-Altman analysis, mean bias at rest was -1.1 mL/min/100 g (CI -3.1; 0.9) with limits of agreement of -27 and 24.8 mL/min/100 g. Mean bias at stress was 6.3 mL/min/100 g (CI -1.1; 14.1) with limits of agreement of -86.9 and 99.9. Mean bias of MPR was 0.11 (CI: -0.02; 0.23) with limits of agreement of -1.43 and 1.64. CONCLUSION: MBF may be determined from coronary sinus blood flow, with acceptable bias, but relatively large limits of agreement, against the reference of MBFDCE . LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diabetes Mellitus Tipo 2 / Seio Coronário / Imagem de Perfusão do Miocárdio Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Dinamarca

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diabetes Mellitus Tipo 2 / Seio Coronário / Imagem de Perfusão do Miocárdio Tipo de estudo: Observational_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Dinamarca