Your browser doesn't support javascript.
loading
Continuous enrichment and trace analysis of tetracyclines in bovine milk using dual-functionalized aqueous biphasic system combined with high-performance liquid chromatography.
Yao, Tian; Zhang, Hanyu; Feng, Cailing; He, Yuchen.
Afiliação
  • Yao T; Key Laboratory of Coarse Cereal Processing, Ministry of Agriculture and Rural Affairs, Sichuan Engineering & Technology Research Center of Coarse Cereal Industralization, School of Food and Biological Engineering, Chengdu University, Chengdu 610106, People's Republic of China. Electronic address
  • Zhang H; Nanchong Key Laboratory of Individualized Drug Therapy, Department of Pharmacy, the Affiliated Nanchong Central Hospital of North Sichuan Medical College, Nanchong 637000, People's Republic of China.
  • Feng C; Key Laboratory of Coarse Cereal Processing, Ministry of Agriculture and Rural Affairs, Sichuan Engineering & Technology Research Center of Coarse Cereal Industralization, School of Food and Biological Engineering, Chengdu University, Chengdu 610106, People's Republic of China.
  • He Y; Key Laboratory of Coarse Cereal Processing, Ministry of Agriculture and Rural Affairs, Sichuan Engineering & Technology Research Center of Coarse Cereal Industralization, School of Food and Biological Engineering, Chengdu University, Chengdu 610106, People's Republic of China.
J Dairy Sci ; 106(9): 5916-5929, 2023 Sep.
Article em En | MEDLINE | ID: mdl-37500441
ABSTRACT
Two PPG1000 based temperature-sensitive magnetic ionic liquid were synthesized and characterized. The temperature-sensitive magnetic ionic liquid aqueous biphasic system combined with HPLC was applied for the continuous enrichment and trace analysis of tetracycline antibiotics (TC) in bovine milk for the first time. High enrichment factors were achieved and the detection was highly sensitive. The trace analysis of TC was rapid, free of organic solvent, recyclable and magnetically assisted for phase separation. Under optimum conditions, wide linear ranges of 0.25-300 ng/mL for all TC, high enrichment factors of 217.7-231.4, good precisions with relative standard deviation in the range of 0.74-3.97%, very low limits of detection of 0.031-0.067 ng/mL, limits of quantification of 0.103-0.223 ng/mL, and good recoveries of 94.28-99.76% were acquired for the proposed analytical method. Real milk analysis was satisfactory. This developed analytical method is showing great potential for trace analysis of targeted analytes in foods and drinks.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Líquidos Iônicos Limite: Animals Idioma: En Revista: J Dairy Sci Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Líquidos Iônicos Limite: Animals Idioma: En Revista: J Dairy Sci Ano de publicação: 2023 Tipo de documento: Article