Your browser doesn't support javascript.
loading
Retinal shadows produced by myopia control spectacles.
de Tomas, Martín; Szeps, Abel; Martín, Gabriel; Suárez, Juan Manuel; Atchison, David A; Rozema, Jos J; Iribarren, Rafael.
Afiliação
  • de Tomas M; International Optics and Ophthalmology, Buenos Aires, Argentina.
  • Szeps A; Department of Ophthalmology, Posadas Hospital Buenos Aires, Buenos Aires, Argentina.
  • Martín G; Opulens (Novar), Buenos Aires, Argentina.
  • Suárez JM; Reichert Technologies, Depew, New York, USA.
  • Atchison DA; Suárez Optical Laboratory, Buenos Aires, Argentina.
  • Rozema JJ; Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.
  • Iribarren R; Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, Antwerp University, Wilrijk, Belgium.
Ophthalmic Physiol Opt ; 44(1): 214-218, 2024 Jan.
Article em En | MEDLINE | ID: mdl-37642972
ABSTRACT

PURPOSE:

To analyse ocular coherence tomography (OCT) images of the retinal shadows caused by defocus and diffusion optics spectacles.

METHODS:

One eye was fitted successively with the Hoya Defocus Incorporated Multiple Segments (DIMS) spectacle lens, two variations of the +3.50 D peripheral add spectacle (DEFOCUS) and the low-contrast dot lens (Diffusion Optics Multiple Segments, DOMS); each at a vertex distance of 12 mm. Simultaneously, a retinal image of the macular region with central fixation was obtained using infrared OCT. The corneal power and intraocular distances were determined using an optical biometer.

RESULTS:

The retinal images for the DIMS and DOMS lenses showed patterns of obvious retinal shadows in the periphery, while the central 10-11° remained clear. The DEFOCUS lens produced a darkened peripheral area. Dividing the size of the retinal pattern, measured with the calliper of the OCT software, by the actual size on the spectacle lens gave a magnification of -0.57 times. This is consistent with the incoming OCT beam being imaged to a position approximately 31 mm beyond the front of the eye. [Correction added on 26 October 2023 after first online publication The preceding paragraph was corrected.]

CONCLUSION:

With device-specific correction, retinal OCT images can help visualise the regions affected by the defocus or lowered contrast induced by myopia control spectacles. This is of potential value for improving myopia therapies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cristalino / Miopia Limite: Humans Idioma: En Revista: Ophthalmic Physiol Opt Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Argentina

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cristalino / Miopia Limite: Humans Idioma: En Revista: Ophthalmic Physiol Opt Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Argentina