High-pitch CT pulmonary angiography (CTPA) with ultra-low contrast medium volume for the detection of pulmonary embolism: a comparison with standard CTPA.
Schönfeld, Tobias; Seitz, Patrick; Krieghoff, Christian; Ponorac, Slavica; Wötzel, Alexander; Olthoff, Stefan; Schaudt, Sebastian; Steglich, Jonas; Gutberlet, Matthias; Gohmann, Robin F.
Afiliação
  • Schönfeld T; Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany.
  • Seitz P; Department of General and Geriatric Medicine, St. Elisabeth-Hospital Leipzig, Biedermannstr. 84, 04277, Leipzig, Germany.
  • Krieghoff C; Medical Faculty, University of Leipzig, Liebigstr. 27, 04103, Leipzig, Germany.
  • Ponorac S; Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany.
  • Wötzel A; Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany.
  • Olthoff S; Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany.
  • Schaudt S; Institute of Radiology, University Medical Centre Ljubljana, Zaloska Cesta 7, 1000, Ljubljana, Slovenia.
  • Steglich J; Emergency Department, Helios Park-Clinic Leipzig, Strümpellstr. 41, 04289, Leipzig, Germany.
  • Gutberlet M; Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany.
  • Gohmann RF; Department of Diagnostic and Interventional Radiology, Heart Center Leipzig, Strümpellstr. 39, 04289, Leipzig, Germany.
Eur Radiol ; 34(3): 1921-1931, 2024 Mar.
Article em En | MEDLINE | ID: mdl-37656178
ABSTRACT

OBJECTIVE:

To investigate the feasibility and image quality of high-pitch CT pulmonary angiography (CTPA) with reduced iodine volume in normal weight patients.

METHODS:

In total, 81 normal weight patients undergoing CTPA for suspected pulmonary arterial embolism were retrospectively included 41 in high-pitch mode with 20 mL of contrast medium (CM); and 40 with normal pitch and 50 mL of CM. Subjective image quality was assessed and rated on a 3-point scale. For objective image quality, attenuation and noise values were measured in all pulmonary arteries from the trunk to segmental level. Contrast-to-noise ratio (CNR) was calculated. Radiation dose estimations were recorded.

RESULTS:

There were no statistically significant differences in patient and scan demographics between high-pitch and standard CTPA. Subjective image quality was rated good to excellent in over 90% of all exams with no significant group differences (p = 0.32). Median contrast opacification was lower in high-pitch CTPA (283.18 [216.06-368.67] HU, 386.81 [320.57-526.12] HU; p = 0.0001). CNR reached a minimum of eight in all segmented arteries, but was lower in high-pitch CTPA (8.79 [5.82-12.42], 11.01 [9.19-17.90]; p = 0.005). Median effective dose of high-pitch CTPA was lower (1.04 [0.72-1.27] mSv/mGy·cm; 1.49 [1.07-2.05] mSv/mGy·cm; p < 0.0001).

CONCLUSION:

High-pitch CTPA using ultra-low contrast volume (20 mL) rendered diagnostic images for the detection of pulmonary arterial embolism in most instances. Compared to standard CTPA, the high-pitch CTPA exams with drastically reduced contrast medium volume had also concomitantly reduced radiation exposure. However, objective image quality of high-pitch CTPA was worse, though likely still within acceptable limits for confident diagnosis. CLINICAL RELEVANCE This study provides valuable insights on the performance of a high-pitch dual-source CTPA protocol, offering potential benefits in reducing contrast medium and radiation dose while maintaining sufficient image quality for accurate diagnosis in patients suspected of pulmonary embolism. KEY POINTS • High-pitch CT pulmonary angiography (CTPA) with ultra-low volume of contrast medium and reduced radiation dose renders diagnostic examinations with comparable subjective image quality to standard CTPA in most patients. • Objective image quality of high-pitch CTPA is reduced compared to standard CTPA, but contrast opacification and contrast-to-noise ratio remain above diagnostic thresholds. • Challenges of high-pitch CTPA may potentially be encountered in patients with severe heart failure or when performing a Valsalva maneuver during the examination.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Embolia Pulmonar / Hipertensão Pulmonar Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Embolia Pulmonar / Hipertensão Pulmonar Tipo de estudo: Diagnostic_studies / Guideline Limite: Humans Idioma: En Revista: Eur Radiol Assunto da revista: RADIOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Alemanha