Your browser doesn't support javascript.
loading
Preliminary results of the 105 GHz collective Thomson scattering system on HL-2A.
Deng, W C; Shi, Z B; Shi, P W; Yang, Z C; Chen, W; Huang, M; Zhang, F; Yu, X; Jiang, M; Wen, J; Liang, A S; Shen, Y Q; Zhou, Y; Tong, R H; Zhong, W L.
Afiliação
  • Deng WC; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Shi ZB; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Shi PW; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Yang ZC; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Chen W; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Huang M; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Zhang F; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Yu X; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Jiang M; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Wen J; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Liang AS; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Shen YQ; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Zhou Y; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Tong RH; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
  • Zhong WL; Southwestern Institute of Physics, P.O. Box 432, Chengdu 610041, China.
Rev Sci Instrum ; 94(9)2023 Sep 01.
Article em En | MEDLINE | ID: mdl-37668510
ABSTRACT
A 105 GHz collective Thomson scattering (CTS) diagnostic has been successfully developed for fast-ion measurements on the HL-2A tokamak, and it has been deployed during an experimental campaign. Enhanced signals exhibiting synchronous modulation characteristics have been observed across all CTS channels upon the launch of a modulated probe wave. Results show that the intensity of the CTS signal increases with Neutral Beam Injection (NBI) power and is proportional to neutron count, indicating that the scattering signal contains a contribution from fast ions. Compared with the signal without NBI, the enhanced scattering spectrum due to NBI is slightly wider than the predicted fast ion range. Such broadening might be attributed to the heating effects of the gyrotron.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2023 Tipo de documento: Article País de afiliação: China