Your browser doesn't support javascript.
loading
Diagnosis of Current Flow Patterns Inside Fault-Simulated Li-Ion Batteries via Non-Invasive, In Operando Magnetic Field Imaging.
Lee, Mingyu; Shin, Yewon; Chang, Hongjun; Jin, Dahee; Lee, Hyuntae; Lim, Minhong; Seo, Jiyeon; Band, Tino; Kaufmann, Kai; Moon, Janghyuk; Lee, Yong Min; Lee, Hongkyung.
Afiliação
  • Lee M; Department of Energy Science and Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-eup, Dalseong-gun, Daegu, 42988, Republic of Korea.
  • Shin Y; Department of Energy Science and Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-eup, Dalseong-gun, Daegu, 42988, Republic of Korea.
  • Chang H; School of Energy Systems Engineering, Chung-Ang University, Heukseok-Ro, Dongjak-Gu, Seoul, 06974, Republic of Korea.
  • Jin D; Department of Energy Science and Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-eup, Dalseong-gun, Daegu, 42988, Republic of Korea.
  • Lee H; Department of Energy Science and Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-eup, Dalseong-gun, Daegu, 42988, Republic of Korea.
  • Lim M; Department of Energy Science and Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-eup, Dalseong-gun, Daegu, 42988, Republic of Korea.
  • Seo J; Department of Energy Science and Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-eup, Dalseong-gun, Daegu, 42988, Republic of Korea.
  • Band T; DENKweit GmbH, Blücherstraße 26, 06120, Halle, Germany.
  • Kaufmann K; Hochschule Anhalt University of Applied Sciences, Bernburger Straße 55, 06366, Köthen, Germany.
  • Moon J; DENKweit GmbH, Blücherstraße 26, 06120, Halle, Germany.
  • Lee YM; School of Energy Systems Engineering, Chung-Ang University, Heukseok-Ro, Dongjak-Gu, Seoul, 06974, Republic of Korea.
  • Lee H; Department of Energy Science and Engineering, Daegu Gyeongbuk Institute of Science and Technology (DGIST), 333 Techno Jungang-daero, Hyeonpung-eup, Dalseong-gun, Daegu, 42988, Republic of Korea.
Small Methods ; 7(11): e2300748, 2023 Nov.
Article em En | MEDLINE | ID: mdl-37712206
ABSTRACT
With the growing popularity of Li-ion batteries in large-scale applications, building a safer battery has become a common goal of the battery community. Although the small errors inside the cells trigger catastrophic failures, tracing them and distinguishing cell failure modes without knowledge of cell anatomy can be challenging using conventional methods. In this study, a real-time, non-invasive magnetic field imaging (MFI) analysis that can signal the battery current-induced magnetic field and visualize the current flow within Li-ion cells is developed. A high-speed, spatially resolved MFI scan is used to derive the current distribution pattern from cells with different tab positions at a current load. Current maps are collected to determine possible cell failures using fault-simulated batteries that intentionally possess manufacturing faults such as lead-tab connection failures, electrode misalignment, and stacking faults (electrode folding). A modified MFI analysis exploiting the magnetic field interference with the countercurrent-carrying plate enables the direct identification of defect spots where abnormal current flow occurs within the pouch cells.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Small Methods Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Small Methods Ano de publicação: 2023 Tipo de documento: Article