Your browser doesn't support javascript.
loading
Role of pinch in Argon impurity transport in ohmic discharges of Aditya-U Tokamak.
Shah, K; Ghosh, J; Patel, S; Chowdhuri, M B; Jadeja, K A; Shukla, G; Macwan, T; Kumar, A; Dolui, S; Singh, K; Tanna, R L; Patel, K M; Dey, R; Manchanda, R; Ramaiya, N; Kumar, R; Aich, S; Yadava, N; Purohit, S; Gupta, M K; Nagora, U C; Pathak, S K; Atrey, P K; Mayya, K B K.
Afiliação
  • Shah K; Department of Physics, Pandit Deendayal Energy University, Raisan, Gandhinagar, 382 007, India. kajal.sphd16@sot.pdpu.ac.in.
  • Ghosh J; Institute for Plasma Research, Bhat, Gandhinagar, 382 428, India. jghosh@ipr.res.in.
  • Patel S; Homi Bhabha National Institute, Training School Complex, Anushaktinagar, Mumbai, 400 094, India. jghosh@ipr.res.in.
  • Chowdhuri MB; Department of Physics, Pandit Deendayal Energy University, Raisan, Gandhinagar, 382 007, India.
  • Jadeja KA; Institute for Plasma Research, Bhat, Gandhinagar, 382 428, India.
  • Shukla G; Institute for Plasma Research, Bhat, Gandhinagar, 382 428, India.
  • Macwan T; Department of Nano Science and Advanced Materials, Saurashtra University, Rajkot, 360 005, India.
  • Kumar A; ITER-India, Institute for Plasma Research, Koteshwar, Ahmedabad, 380 005, India.
  • Dolui S; University of California, Los Angeles, CA, 90095, USA.
  • Singh K; Institute for Plasma Research, Bhat, Gandhinagar, 382 428, India.
  • Tanna RL; Homi Bhabha National Institute, Training School Complex, Anushaktinagar, Mumbai, 400 094, India.
  • Patel KM; Institute for Plasma Research, Bhat, Gandhinagar, 382 428, India.
  • Dey R; Homi Bhabha National Institute, Training School Complex, Anushaktinagar, Mumbai, 400 094, India.
  • Manchanda R; Institute for Plasma Research, Bhat, Gandhinagar, 382 428, India.
  • Ramaiya N; Homi Bhabha National Institute, Training School Complex, Anushaktinagar, Mumbai, 400 094, India.
  • Kumar R; Institute for Plasma Research, Bhat, Gandhinagar, 382 428, India.
  • Aich S; Institute of Science, Nirma University, Ahmedabad, 382 481, India.
  • Yadava N; Institute for Plasma Research, Bhat, Gandhinagar, 382 428, India.
  • Purohit S; Institute for Plasma Research, Bhat, Gandhinagar, 382 428, India.
  • Gupta MK; Institute for Plasma Research, Bhat, Gandhinagar, 382 428, India.
  • Nagora UC; Institute for Plasma Research, Bhat, Gandhinagar, 382 428, India.
  • Pathak SK; Institute for Plasma Research, Bhat, Gandhinagar, 382 428, India.
  • Atrey PK; Institute for Plasma Research, Bhat, Gandhinagar, 382 428, India.
  • Mayya KBK; Institute of Science, Nirma University, Ahmedabad, 382 481, India.
Sci Rep ; 13(1): 16087, 2023 Sep 26.
Article em En | MEDLINE | ID: mdl-37752170
ABSTRACT
We present experimental results of the trace argon impurity puffing in the ohmic plasmas of Aditya-U tokamak performed to study the argon transport behaviour. Argon line emissions in visible and Vacuum Ultra Violet (VUV) spectral ranges arising from the plasma edge and core respectively are measured simultaneously. During the experiments, space resolved brightness profile of Ar1+ line emissions at 472.69 nm (3p44s 2P3/2-3p44p 2D3/2), 473.59 nm (3p44s 4P5/2-3p44p 4P3/2), 476.49 nm (3p44s 2P1/2-3p44p 2P3/2), 480.60 nm (3p44s 4P5/2-3p44p 4P5/2) are recorded using a high resolution visible spectrometer. Also, a VUV spectrometer has been used to simultaneously observe Ar13+ line emission at 18.79 nm (2s22p 2P3/2-2s2p2 2P3/2) and Ar14+ line emission at 22.11 nm (2s2 1S0-2s2p 1P1). The diffusivity and convective velocity of Ar are obtained by comparing the measured radial emissivity profile of Ar1+ emission and the line intensity ratio of Ar13+ and Ar14+ ions, with those simulated using the impurity transport code, STRAHL. Argon diffusivities ~ 12 m2/s and ~ 0.3 m2/s have been observed in the edge (ρ > 0.85) and core region of the Aditya-U, respectively. The diffusivity values both in the edge and core region are found to be higher than the neo-classical values suggesting that the argon impurity transport is mainly anomalous in the Aditya-U tokamak. Also, an inward pinch of ~ 10 m/s mainly driven by Ware pinch is required to match the measured and simulated data. The measured peaked profile of Ar density suggests impurity accumulation in these discharges.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Sci Rep Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Índia