Your browser doesn't support javascript.
loading
Can the inner eye canthus temperature be used as an alternative method to measure core temperature in sleep-deprived individuals?
Costa, Carlos Magno Amaral; Narciso, Fernanda Veruska; Brant, Valdênio Martins; Silva, Andressa; Borba, Diego de Alcantara; Rosa, João Paulo Pereira; Wanner, Samuel Penna; Romano-Silva, Marco Aurélio; de Mello, Marco Túlio.
Afiliação
  • Costa CMA; Exercise Physiology Laboratory, Instituto Federal do Sudeste de Minas Gerais, Campus Rio Pomba, Rio Pomba, Minas Gerais, Brazil; Center for Psychobiology and Exercise Studies, Department of Sports, Physical Education School, Physiotherapy and Occupational Therapy, Universidade Federal de Minas Gerai
  • Narciso FV; Center for Psychobiology and Exercise Studies, Department of Sports, Physical Education School, Physiotherapy and Occupational Therapy, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil; Centro Universitário Mario Palmério (UNIFUCAMP), Monte Carmelo, Minas Gerais, Brazil. El
  • Brant VM; Center for Psychobiology and Exercise Studies, Department of Sports, Physical Education School, Physiotherapy and Occupational Therapy, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil. Electronic address: valdeniombrant@gmail.com.
  • Silva A; Center for Psychobiology and Exercise Studies, Department of Sports, Physical Education School, Physiotherapy and Occupational Therapy, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil. Electronic address: andressa@demello.net.br.
  • Borba DA; Center for Psychobiology and Exercise Studies, Department of Sports, Physical Education School, Physiotherapy and Occupational Therapy, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil; Department of Science and of Movement, Universidade do Estado de Minas Gerais, Divinópol
  • Rosa JPP; Center for Psychobiology and Exercise Studies, Department of Sports, Physical Education School, Physiotherapy and Occupational Therapy, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil; Department of Physical Education, Bioscience Institute, Universidade Estadual Paulista,
  • Wanner SP; Center for Psychobiology and Exercise Studies, Department of Sports, Physical Education School, Physiotherapy and Occupational Therapy, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil. Electronic address: spwanner@hotmail.com.
  • Romano-Silva MA; Department of Psychiatry, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil. Electronic address: romano-silva@ufmg.br.
  • de Mello MT; Center for Psychobiology and Exercise Studies, Department of Sports, Physical Education School, Physiotherapy and Occupational Therapy, Universidade Federal de Minas Gerais, Belo Horizonte, Minas Gerais, Brazil. Electronic address: tmello@demello.net.br.
J Therm Biol ; 117: 103716, 2023 Oct.
Article em En | MEDLINE | ID: mdl-37806067
ABSTRACT
Core temperature is used in several situations, including studies on biological rhythms and circadian markers of physical performance. Measuring the inner eye canthus (Tco) temperature is a method proposed to identify core temperature, but it has shown little concordance in physical exercise situations and has not yet been used in studies with measurements taken throughout the day. The objective of this study was to compare the measurements and daily behavior of Tco obtained by infrared thermography with rectal temperature (Tre) during a prolonged waking protocol. Eleven male individuals participated in the study, who remained in the laboratory for at least 38 h using an actigraph to determine the wakefulness time and were monitored during the entire period. The Tre and Tco measurements were performed every 3 h. The ANOVA was used for repeated measurements followed by Bonferroni's post-hoc test to find the limits of concordance/proximity, while the Bland and Altman method and the Intraclass Correlation Coefficient were used to establish the reliability between the pairs. The significance level adopted was p < 0.05. The results demonstrate significant differences, low levels of concordance and unsatisfactory reliability levels between Tco and Tre at all 13 analyzed moments, in addition to not showing measurement reliability when all data are used together with the 143 temperature measurements. Daily behavior analysis shows moments with similar behavior with an increase in Tco and Tre, but at other times the behavior was the opposite, with a decrease in one measurement and an increase in the other. Based on the results presented, it is not recommended to use the inner eye canthus temperature as a substitute for rectal temperature for measuring core temperature at different times of the day or in sleep-deprived individuals.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Temperatura Corporal / Termografia Limite: Humans / Male Idioma: En Revista: J Therm Biol Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Temperatura Corporal / Termografia Limite: Humans / Male Idioma: En Revista: J Therm Biol Ano de publicação: 2023 Tipo de documento: Article