A clinical tip for conservative retrieval of fractured abutment screw.
J Indian Prosthodont Soc
; 23(4): 398-400, 2023.
Article
em En
| MEDLINE
| ID: mdl-37861618
Fractures of the abutment screw are an extremely dreadful and taxing experience even for experienced clinicians. Retrieval of fractured screw segments due to excessive torque and improperly placed implants pose a great challenge to the clinician. The authors present a case wherein the fractured abutment screw was retrieved successfully with the help of an intraoral plastic mixing tip of light body putty material. The intraoral plastic mixing tips are a more readily available, cost-effective, and feasible alternative to other means of screw retrieval like ultrasonic scalers, endodontic files, and screw retrieval kits.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Parafusos Ósseos
/
Dente Suporte
Idioma:
En
Revista:
J Indian Prosthodont Soc
Ano de publicação:
2023
Tipo de documento:
Article
País de afiliação:
Índia