Your browser doesn't support javascript.
loading
The inter-laboratory validation study of EpiSensA for predicting skin sensitization potential.
Mizumachi, Hideyuki; Watanabe, Mika; Ikezumi, Mayu; Kajiwara, Michika; Yasuda, Michiyo; Mizuno, Makoto; Imai, Noriyasu; Sakuma, Megumi; Shibata, Momoko; Watanabe, Shin-Ichi; Motoyama, Junko; Basketter, David; Eskes, Chantra; Hoffmann, Sebastian; Lehmann, David M; Ashikaga, Takao; Sozu, Takashi; Takeyoshi, Masahiro; Suzuki, Sho; Miyazawa, Masaaki; Kojima, Hajime.
Afiliação
  • Mizumachi H; R&D Safety Science Research, Kao Corporation, 2606 Akabane, Ichikai-Machi, Haga-Gun, Tochigi, 321-3497, Japan.
  • Watanabe M; Food and Drug Safety Center, Hatano Research Institute, 729-5 Ochiai, Hadano, Kanagawa, 257-8523, Japan.
  • Ikezumi M; Food and Drug Safety Center, Hatano Research Institute, 729-5 Ochiai, Hadano, Kanagawa, 257-8523, Japan.
  • Kajiwara M; Food and Drug Safety Center, Hatano Research Institute, 729-5 Ochiai, Hadano, Kanagawa, 257-8523, Japan.
  • Yasuda M; Food and Drug Safety Center, Hatano Research Institute, 729-5 Ochiai, Hadano, Kanagawa, 257-8523, Japan.
  • Mizuno M; Safety and Analytical Research Laboratories, KOSÉ Corporation, 48-18 Sakae-cho, Kita-ku, Tokyo, 114-0005, Japan.
  • Imai N; Safety and Analytical Research Laboratories, KOSÉ Corporation, 48-18 Sakae-cho, Kita-ku, Tokyo, 114-0005, Japan.
  • Sakuma M; Safety and Analytical Research Laboratories, KOSÉ Corporation, 48-18 Sakae-cho, Kita-ku, Tokyo, 114-0005, Japan.
  • Shibata M; Safety and Analytical Research Laboratories, KOSÉ Corporation, 48-18 Sakae-cho, Kita-ku, Tokyo, 114-0005, Japan.
  • Watanabe SI; Safety Research Science Laboratory, LION Corporation, 100 Tajima, Odawara-shi, Kanagawa, 256-0811, Japan.
  • Motoyama J; Safety Research Science Laboratory, LION Corporation, 100 Tajima, Odawara-shi, Kanagawa, 256-0811, Japan.
  • Basketter D; DABMEB Consultancy Ltd., Kingswood, Gloucestershire, GL12 8RN, UK.
  • Eskes C; Services and Consultation on Alternative Methods (SeCAM), Magliaso, Switzerland and Swiss 3R Competence Centre (3RCC), Bern, Switzerland.
  • Hoffmann S; seh consulting + services, Stembergring 15, Paderborn, 33106, Germany.
  • Lehmann DM; Office of Research and Development, US Environmental Protection Agency, 109 T.W. Alexander Drive, Research Triangle Park, NC, 27709, USA.
  • Ashikaga T; Japanese Center for the Validation of Alternative Methods (JaCVAM), National Institute of Health Sciences, 3-25-26 Tonomachi, Kawasaki-ku, Kanagawa, 210-9501, Japan.
  • Sozu T; Department of Information and Computer Technology, Faculty of Engineering, Tokyo University of Science, Katsushika-ku, Tokyo, 125-0051, Japan.
  • Takeyoshi M; Chemicals Assessment and Research Center, Chemicals Evaluation and Research Institute (CERI), 1600 Shimotakano, Sugito-machi, Kitakatsushika-gun, Saitama, 345-0043, Japan.
  • Suzuki S; R&D Safety Science Research, Kao Corporation, 2606 Akabane, Ichikai-Machi, Haga-Gun, Tochigi, 321-3497, Japan.
  • Miyazawa M; R&D Safety Science Research, Kao Corporation, 2606 Akabane, Ichikai-Machi, Haga-Gun, Tochigi, 321-3497, Japan.
  • Kojima H; Japanese Center for the Validation of Alternative Methods (JaCVAM), National Institute of Health Sciences, 3-25-26 Tonomachi, Kawasaki-ku, Kanagawa, 210-9501, Japan.
J Appl Toxicol ; 44(4): 510-525, 2024 Apr.
Article em En | MEDLINE | ID: mdl-37897225
ABSTRACT
The Epidermal Sensitization Assay (EpiSensA) is a reconstructed human epidermis (RhE)-based gene expression assay for predicting the skin sensitization potential of chemicals. Since the RhE model is covered by a stratified stratum corneum, various kinds of test chemicals, including lipophilic ones and pre-/pro-haptens, can be tested with a route of exposure akin to an in vivo assay and human exposure. This article presents the results of a formally managed validation study of the EpiSensA that was carried out by three participating laboratories. The purpose of this validation study was to assess transferability of the EpiSensA to new laboratories along with its within- (WLR) and between-laboratory reproducibility (BLR). The validation study was organized into two independent stages. As demonstrated during the first stage, where three sensitizers and one non-sensitizer were correctly predicted by all participating laboratories, the EpiSensA was successfully transferred to all three participating laboratories. For Phase I of the second stage, each participating laboratory performed three experiments with an identical set of 15 coded test chemicals resulting in WLR of 93.3%, 93.3%, and 86.7%, respectively. Furthermore, when the results from the 15 test chemicals were combined with those of the additional 12 chemicals tested in Phase II of the second stage, the BLR for 27 test chemicals was 88.9%. Moreover, the predictive capacity among the three laboratories showed 92.6% sensitivity, 63.0% specificity, 82.7% accuracy, and 77.8% balanced accuracy based on murine local lymph node assay (LLNA) results. Overall, this validation study concluded that EpiSensA is easily transferable and sufficiently robust for assessing the skin sensitization potential of chemicals.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Alérgenos / Dermatite Alérgica de Contato Limite: Animals / Humans Idioma: En Revista: J Appl Toxicol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Alérgenos / Dermatite Alérgica de Contato Limite: Animals / Humans Idioma: En Revista: J Appl Toxicol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão