Self-Supervised Deep Unrolled Reconstruction Using Regularization by Denoising.
IEEE Trans Med Imaging ; 43(3): 1203-1213, 2024 Mar.
Article em En | MEDLINE | ID: mdl-37962993
ABSTRACT
Deep learning methods have been successfully used in various computer vision tasks. Inspired by that success, deep learning has been explored in magnetic resonance imaging (MRI) reconstruction. In particular, integrating deep learning and model-based optimization methods has shown considerable advantages. However, a large amount of labeled training data is typically needed for high reconstruction quality, which is challenging for some MRI applications. In this paper, we propose a novel reconstruction method, named DURED-Net, that enables interpretable self-supervised learning for MR image reconstruction by combining a self-supervised denoising network and a plug-and-play method. We aim to boost the reconstruction performance of Noise2Noise in MR reconstruction by adding an explicit prior that utilizes imaging physics. Specifically, the leverage of a denoising network for MRI reconstruction is achieved using Regularization by Denoising (RED). Experiment results demonstrate that the proposed method requires a reduced amount of training data to achieve high reconstruction quality among the state-of-the-art approaches utilizing Noise2Noise.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: IEEE Trans Med Imaging Ano de publicação: 2024 Tipo de documento: Article