Your browser doesn't support javascript.
loading
Performance Evaluation of an Immersive Virtual Reality Application for Rehabilitation after Arthroscopic Rotator Cuff Repair.
Carnevale, Arianna; Mannocchi, Ilaria; Schena, Emiliano; Carli, Marco; Sassi, Mohamed Saifeddine Hadj; Marino, Martina; Longo, Umile Giuseppe.
Afiliação
  • Carnevale A; Fondazione Policlinico Universitario Campus Bio-Medico, Via Álvaro del Portillo, 200, 00128 Roma, Italy.
  • Mannocchi I; Department of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, Via Vito Volterra, 62, 00146 Roma, Italy.
  • Schena E; Unit of Measurement and Biomedical Instrumentation, Department of Engineering, Università Campus Bio-Medico di Roma, Via Álvaro del Portillo, 21, 00128 Roma, Italy.
  • Carli M; Department of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, Via Vito Volterra, 62, 00146 Roma, Italy.
  • Sassi MSH; Department of Industrial, Electronic and Mechanical Engineering, University of Roma Tre, Via Vito Volterra, 62, 00146 Roma, Italy.
  • Marino M; Fondazione Policlinico Universitario Campus Bio-Medico, Via Álvaro del Portillo, 200, 00128 Roma, Italy.
  • Longo UG; Fondazione Policlinico Universitario Campus Bio-Medico, Via Álvaro del Portillo, 200, 00128 Roma, Italy.
Bioengineering (Basel) ; 10(11)2023 Nov 10.
Article em En | MEDLINE | ID: mdl-38002429
ABSTRACT
Few studies have evaluated the effectiveness of shoulder rehabilitation in virtual environments. The objective of this study was to investigate the performance of a custom virtual reality application (VR app) with a stereophotogrammetric system considered the gold standard. A custom VR app was designed considering the recommended rehabilitation exercises following arthroscopic rotator cuff repair. Following the setting of the play space, the user's arm length, and height, five healthy volunteers performed four levels of rehabilitative exercises. Results for the first and second rounds of flexion and abduction displayed low total mean absolute error values and low numbers of unmet conditions. In internal and external rotation, the number of times conditions were not met was slightly higher; this was attributed to a lack of isolated shoulder movement. Data is promising, and volunteers were able to reach goal conditions more often than not. Despite positive results, more literature comparing VR applications with gold-standard clinical parameters is necessary. Nevertheless, results contribute to a body of literature that continues to encourage the application of VR to shoulder rehabilitation programs.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Bioengineering (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Itália

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Bioengineering (Basel) Ano de publicação: 2023 Tipo de documento: Article País de afiliação: Itália