Wide-field time-of-flight measurements of highly scattering media.
Opt Lett ; 48(24): 6396-6399, 2023 Dec 15.
Article em En | MEDLINE | ID: mdl-38099757
ABSTRACT
We present a setup that makes use of a time-resolved single-photon camera to determine the scattering parameters of media. The measurement is realized in a non-contact way, both for the illumination laser and the detection. By fitting the time-of-flight acquired distributions at different spatial positions with the diffusion equation, we retrieve the reduced scattering coefficients of a highly diffusive isotropic reference media for wavelengths in the range from 540 to 840 nm.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Opt Lett Ano de publicação: 2023 Tipo de documento: Article