Assessment of the Influence of the Geometrical Shape of the Damper on the Efficiency of an Ultrasonic Operation Piezoelectric Transducer.
Sensors (Basel)
; 23(24)2023 Dec 06.
Article
em En
| MEDLINE
| ID: mdl-38139508
ABSTRACT
The results of a study on the geometric shape of the damper on the efficiency of the ultrasonic piezoelectric transducer are presented. In particular, a damper in the form of a truncated cone is considered, the generatrix of which has an inclination angle α relative to the diameter of the piezoceramic plate. The shape of the damper in the form of a truncated cone is chosen based on the a priori assumption that this helps to increase the path of the wave in the damper material due to numerous reflections in it. A criterion for the efficiency of damper operation is proposed. The optimal (from the point of view of the damper efficiency) value of the angle α was determined theoretically and experimentally. The technology of its production is described. Satisfactory agreement between the results of theoretical and experimental studies was noted.