Your browser doesn't support javascript.
loading
Single-shot diffusion trace-weighted MR spectroscopy: Comparison with unipolar and bipolar diffusion-weighted point-resolved spectroscopy.
Saucedo, Andres; Sayre, James; Thomas, M Albert.
Afiliação
  • Saucedo A; Department of Radiological Sciences, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, California, USA.
  • Sayre J; Physics and Biology in Medicine Interdepartmental Graduate Program, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, California, USA.
  • Thomas MA; Department of Radiological Sciences, David Geffen School of Medicine, University of California at Los Angeles, Los Angeles, California, USA.
NMR Biomed ; 37(4): e5090, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38148181
ABSTRACT
This study demonstrates the feasibility and performance of the point-resolved spectroscopy (PRESS)-based, single-shot diffusion trace-weighted sequence in quantifying the trace apparent diffusion coefficient (ADC) in phantom and in vivo using a 3-T MRI/MRS scanner. The single-shot diffusion trace-weighted PRESS sequence was implemented and compared with conventional diffusion-weighted (DW)-PRESS variants using bipolar and unipolar diffusion-sensitizing gradients. Nine phantom datasets were acquired using each sequence, and seven volunteers were scanned in three different brain regions to determine the range and variability of trace ADC values, and to allow a comparison of trace ADCs among the sequences. This sequence results in a comparatively stable range of trace ADC values that are statistically significantly higher than those produced from unipolar and bipolar DW-PRESS sequences. Only total n-acetylaspartate, total creatine, and total choline were reliably estimated in all sequences with Cramér-Rao lower bounds of, at most, 20%. The larger trace ADCs from the single-shot sequences are probably attributable to the shorter diffusion time relative to the other sequences. Overall, this study presents the first demonstration of the single-shot diffusion trace-weighted sequence in a clinical scanner at 3 T. The results show excellent agreement of phantom trace ADCs computed with all sequences, and in vivo ADCs agree well with the expected differences between gray and white matter. The diffusion trace-weighted sequence could provide an estimate of the trace ADC in a shorter scan time (by nearly a factor of 3) compared with conventional DW-PRESS approaches that require three separate orthogonal directions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Substância Branca Limite: Humans Idioma: En Revista: NMR Biomed Assunto da revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Encéfalo / Substância Branca Limite: Humans Idioma: En Revista: NMR Biomed Assunto da revista: DIAGNOSTICO POR IMAGEM / MEDICINA NUCLEAR Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos