Your browser doesn't support javascript.
loading
Fluorometric and colorimetric quantitative analysis platform for acid phosphatase by cerium ions-directed AIE and oxidase-like activity.
Li, Qing; Gao, Yue; Liu, Si-Hua.
Afiliação
  • Li Q; College of Life Science and Chemistry, Hunan University of Technology, Zhuzhou, 412007, China. qingli@hut.edu.cn.
  • Gao Y; State Key Laboratory of Chemo/Bio-Sensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, 410082, People's Republic of China. qingli@hut.edu.cn.
  • Liu SH; College of Life Science and Chemistry, Hunan University of Technology, Zhuzhou, 412007, China.
Anal Bioanal Chem ; 416(5): 1179-1188, 2024 Feb.
Article em En | MEDLINE | ID: mdl-38148365
ABSTRACT
A facile and sensitive fluorescent and colorimetric dual-readout assay for detection of acid phosphatase (ACP) was developed via Ce(III) ions-directed aggregation-induced emission (AIE) of glutathione-protected gold nanoclusters (GSH-AuNCs) and oxidase-mimicking activity of Ce(IV) ions. Free Ce(IV) ions exhibited a strong oxidase-mimetic activity, catalytically oxidizing colorless 3,3',5,5'-tetramethylbenzidine (TMB) into its blue product oxTMB in the presence of dissolved O2, thus triggering a remarkable color reaction detected visually. ACP can hydrolyze L-ascorbic acid-2-phosphate (AAP) with the production of ascorbic acid (AA). The AA is able to reduce Ce(IV) ions to Ce(III) ions, thus quenching the oxidase-mimetic activity of Ce(IV) ions. Meanwhile, Ce(III) ions induce AIE of GSH-AuNCs, resulting in the enhancement of the fluorescence signal of GSH-AuNCs. Both the fluorescent and colorimetric dual-mode analysis platforms exhibit a sensitive response to ACP, providing detection limits as low as 0.101 U/L and 0.200 U/L, respectively. Besides, this fabricated dual-mode detection platform holds the potential for analysis of ACP in human serum samples and screening inhibitors for ACP. With good performance and practicability, this study shows promising application in the convenient and reliable determination of ACP activity.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosfatase Ácida / Cério Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fosfatase Ácida / Cério Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China