Your browser doesn't support javascript.
loading
Mechanistic modelling of relative biological effectiveness of carbon ion beams and comparison with experiments.
Feng, Haonan; Li, Weiguang; Zhang, Yibao; Chang, Cheng; Hua, Ling; Feng, Yiwen; Lai, Youfang; Geng, LiSheng.
Afiliação
  • Feng H; School of Physics, Beihang University, Beijing 102206, People's Republic of China.
  • Li W; Department of Medical Management, Chinese Academy of Science Heavy Ion Medicine (CASHIM) Co. Ltd, Beijing 100083, People's Republic of China.
  • Zhang Y; School of Physics, Beihang University, Beijing 102206, People's Republic of China.
  • Chang C; Department of Medical Management, Chinese Academy of Science Heavy Ion Medicine (CASHIM) Co. Ltd, Beijing 100083, People's Republic of China.
  • Hua L; Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Radiation Oncology, Peking University Cancer Hospital & Institute, Beijing 100142, People's Republic of China.
  • Feng Y; Department of Medical Management, Chinese Academy of Science Heavy Ion Medicine (CASHIM) Co. Ltd, Beijing 100083, People's Republic of China.
  • Lai Y; Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing), Department of Radiation Oncology, Peking University Cancer Hospital & Institute, Beijing 100142, People's Republic of China.
  • Geng L; Beijing University of Posts and Telecommunications, Beijing 100876, People's Republic of China.
Phys Med Biol ; 69(3)2024 Jan 31.
Article em En | MEDLINE | ID: mdl-38157549
ABSTRACT
Objective.Relative biological effectiveness (RBE) plays a vital role in carbon ion radiotherapy, which is a promising treatment method for reducing toxic effects on normal tissues and improving treatment efficacy. It is important to have an effective and precise way of obtaining RBE values to support clinical decisions. A method of calculating RBE from a mechanistic perspective is reported.Approach.Ratio of dose to obtain the same number of double strand breaks (DSBs) between different radiation types was used to evaluate RBE. Package gMicroMC was used to simulate DSB yields. The DSB inductions were then analyzed to calculate RBE. The RBE values were compared with experimental results.Main results.Furusawa's experiment yielded RBE values of 1.27, 2.22, 3.00 and 3.37 for carbon ion beam with dose-averaged LET of 30.3 keVµm-1, 54.5 keVµm-1, 88 keVµm-1and 137 keVµm-1, respectively. RBE values computed from gMicroMC simulations were 1.75, 2.22, 2.87 and 2.97. When it came to a more sophisticated carbon ion beam with 6 cm spread-out Bragg peak, RBE values were 1.61, 1.63, 2.19 and 2.36 for proximal, middle, distal and distal end part, respectively. Values simulated by gMicroMC were 1.50, 1.87, 2.19 and 2.34. The simulated results were in reasonable agreement with the experimental data.Significance.As a mechanistic way for the evaluation of RBE for carbon ion radiotherapy by combining the macroscopic simulation of energy spectrum and microscopic simulation of DNA damages, this work provides a promising tool for RBE calculation supporting clinical applications such as treatment planning.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Carbono / Radioterapia com Íons Pesados Idioma: En Revista: Phys Med Biol Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Carbono / Radioterapia com Íons Pesados Idioma: En Revista: Phys Med Biol Ano de publicação: 2024 Tipo de documento: Article