Your browser doesn't support javascript.
loading
A comparative evaluation of the analytical performances of premier resolution-high-performance liquid chromatography (PR-HPLC) with capillary zone electrophoresis (CZE) assays for the detection of hemoglobin variants and the quantitation of HbA0, A2, E, and F.
Laksap, Sirikwan; Suanboon, Suphisara; Punyamung, Manoo; Ruengdit, Chedtapak; Pornprasert, Sakorn.
Afiliação
  • Laksap S; Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand.
  • Suanboon S; Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand.
  • Punyamung M; Associated Medical Sciences Clinical Service Center, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand.
  • Ruengdit C; Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand.
  • Pornprasert S; Department of Medical Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai, Thailand.
Clin Chem Lab Med ; 62(7): 1383-1392, 2024 Jun 25.
Article em En | MEDLINE | ID: mdl-38197862
ABSTRACT

OBJECTIVES:

Hemoglobinopathies, including thalassemia and hemoglobin (Hb) variants, are common hematological disorders in tropical countries. Accurate and precise separation of hemoglobin types and reliable quantitation are necessary for differential diagnosis of these disorders.

METHODS:

We have evaluated the analytical performances of premier resolution-high-performance liquid chromatography (PR-HPLC; Trinity Biotech, Co. Wicklow, Ireland) to assist in the presumptive diagnosis of thalassemia and Hb variants commonly found in Southeast Asian countries. HbA0, HbA2, HbE, and HbF levels were separated and quantified in 120 blood samples from unrelated adult subjects and compared with those analyzed by capillary zone electrophoresis (CZE; CAPILLARYS™ 2, Sebia, Norcross, GA, US). The Hb analysis patterns of Hb variants obtained from the PR-HPLC system were also compared to those obtained from HPLC (VARIANT II, ß-thalassemia Short Program, Bio-Rad, Laboratories, Hercules, CA, US) and CZE systems.

RESULTS:

The PR-HPLC had excellent precision with a coefficient of variation (CV) for HbA2 quantitation of 3.8 % within-run and 5.2 % between-run. The levels of HbA2/E quantified by the PR-HPLC system correlated well with those of the CZE system (r=0.997). In addition, thalassemia interpretation results obtained from the PR-HPLC and the CZE showed 100 % agreement. Moreover, chromatograms of the PR-HPLC were also comparable to those of VII-HPLC and CAP2-CZE electropherograms.

CONCLUSIONS:

The PR-HPLC system would be applicable to diagnose common forms of thalassemia and Hb variants in Southeast Asia.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletroforese Capilar Tipo de estudo: Diagnostic_studies Limite: Adult / Humans Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Tailândia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Eletroforese Capilar Tipo de estudo: Diagnostic_studies Limite: Adult / Humans Idioma: En Revista: Clin Chem Lab Med Assunto da revista: QUIMICA CLINICA / TECNICAS E PROCEDIMENTOS DE LABORATORIO Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Tailândia