Your browser doesn't support javascript.
loading
Enhancing Nigrosome-1 Sign Identification via Interpretable AI using True Susceptibility Weighted Imaging.
Wang, Chenglong; He, Naying; Zhang, Youmin; Li, Yan; Huang, Pei; Liu, Yu; Jin, Zhijia; Cheng, Zenghui; Liu, Yun; Wang, Yida; Zhang, Chengxiu; Haacke, E Mark; Chen, Shengdi; Yan, Fuhua; Yang, Guang.
Afiliação
  • Wang C; Shanghai Key Laboratory of Magnetic Resonance, East China Normal University, Shanghai, China.
  • He N; Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Zhang Y; Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Li Y; Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Huang P; Department of Neurology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Liu Y; Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Jin Z; Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Cheng Z; Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Liu Y; Shanghai Key Laboratory of Magnetic Resonance, East China Normal University, Shanghai, China.
  • Wang Y; Shanghai Key Laboratory of Magnetic Resonance, East China Normal University, Shanghai, China.
  • Zhang C; Shanghai Key Laboratory of Magnetic Resonance, East China Normal University, Shanghai, China.
  • Haacke EM; Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Chen S; Department of Biomedical Engineering, Wayne State University, Detroit, Michigan, USA.
  • Yan F; Department of Neurology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
  • Yang G; Department of Radiology, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
J Magn Reson Imaging ; 2024 Jan 18.
Article em En | MEDLINE | ID: mdl-38236577
ABSTRACT

BACKGROUND:

Nigrosome 1 (N1), the largest nigrosome region in the ventrolateral area of the substantia nigra pars compacta, is identifiable by the "N1 sign" in long echo time gradient echo MRI. The N1 sign's absence is a vital Parkinson's disease (PD) diagnostic marker. However, it is challenging to visualize and assess the N1 sign in clinical practice.

PURPOSE:

To automatically detect the presence or absence of the N1 sign from true susceptibility weighted imaging by using deep-learning method. STUDY TYPE Prospective. POPULATION/

SUBJECTS:

453 subjects, including 225 PD patients, 120 healthy controls (HCs), and 108 patients with other movement disorders, were prospectively recruited including 227 males and 226 females. They were divided into training, validation, and test cohorts of 289, 73, and 91 cases, respectively. FIELD STRENGTH/SEQUENCE 3D gradient echo SWI sequence at 3T; 3D multiecho strategically acquired gradient echo imaging at 3T; NM-sensitive 3D gradient echo sequence with MTC pulse at 3T. ASSESSMENT A neuroradiologist with 5 years of experience manually delineated substantia nigra regions. Two raters with 2 and 36 years of experience assessed the N1 sign on true susceptibility weighted imaging (tSWI), QSM with high-pass filter, and magnitude data combined with MTC data. We proposed NINet, a neural model, for automatic N1 sign identification in tSWI images. STATISTICAL TESTS We compared the performance of NINet to the subjective reference standard using Receiver Operating Characteristic analyses, and a decision curve analysis assessed identification accuracy.

RESULTS:

NINet achieved an area under the curve (AUC) of 0.87 (CI 0.76-0.89) in N1 sign identification, surpassing other models and neuroradiologists. NINet localized the putative N1 sign within tSWI images with 67.3% accuracy. DATA

CONCLUSION:

Our proposed NINet model's capability to determine the presence or absence of the N1 sign, along with its localization, holds promise for enhancing diagnostic accuracy when evaluating PD using MR images. LEVEL OF EVIDENCE 2 TECHNICAL EFFICACY Stage 1.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China