Your browser doesn't support javascript.
loading
Pyrenecarboxaldehyde@Graphene Oxide Acted as a Highly Efficient ECL Emitter and Target-Triggered the Recyclable Cascade System as an Amplifier for Ultrasensitive APE1 Activity Detection.
Chai, Duo-Duo; Zhuo, Ying; Zhao, Mei-Ling; Li, Hong-Ling; Yuan, Ruo; Wei, Sha-Ping.
Afiliação
  • Chai DD; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
  • Zhuo Y; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
  • Zhao ML; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
  • Li HL; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
  • Yuan R; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
  • Wei SP; Key Laboratory of Luminescence Analysis and Molecular Sensing (Southwest University), Ministry of Education, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, P. R. China.
ACS Sens ; 9(2): 955-961, 2024 02 23.
Article em En | MEDLINE | ID: mdl-38251427
ABSTRACT
Herein, pyrenecarboxaldehyde@graphene oxide (Pyc@GO) sheets with highly efficient electrochemiluminescence (ECL) as emitters were prepared by a noncovalent combination to develop a neoteric ECL biosensing platform for the ultrasensitive assessment of human apurinic/apyrimidinic endonuclease1 (APE1) activity. Impressively, the pyrenecarboxaldehyde (Pyc) molecules were able to form stable polar functional groups on the surface of GO sheets through the noncovalent π-π stacking mechanism to prevent intermolecular restacking and simultaneously generate Pyc@GO sheets. Compared with the tightly packed PAH nanocrystals, the Pyc@GO sheets significantly reduced internal filtering effects and diminished nonactivated emitters to enhance ECL intensity and achieve strong ECL emission. Furthermore, the APE1-activated initiators could trigger the recyclable cascade amplified system based on the synergistic cross-activation between catalytic hairpin assembly (CHA) and DNAzyme, which improved the signal amplification and transduction ability. Consequently, the developed ECL platform for the detection of APE1 activity displayed exceptional sensitivity with a low detection limit of 4.6 × 10-9 U·mL-1 ranging from 10-8 to 10-2 U·mL-1. Therefore, the proposed strategy holds great promise for the future development of sensitive and reliable biosensing platforms for the detection of various biomarkers.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: DNA Catalítico / Nanopartículas / Grafite Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: ACS Sens Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: DNA Catalítico / Nanopartículas / Grafite Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: ACS Sens Ano de publicação: 2024 Tipo de documento: Article