ABSTRACT

BACKGROUND:

Gait abnormalities such as Trendelenburg gait (TG) in patients who have hip osteoarthritis (OA) have traditionally been evaluated using clinicians' visual assessment. Recent advances in portable inertial gait sensors offer more sensitive, quantitative methods for gait assessment in clinical settings. This study sought to compare sensor-derived metrics in a cohort of hip OA patients when stratified by clinical TG severity.

METHODS:

There were 42 patients who had hip OA and were grouped by TG severity (mild, moderate, and severe) through visual assessment by a single arthroplasty surgeon who had > 30 years of experience. After informed consent, wireless inertial sensors placed at the midpoint of the intercristal line collected gait parameters including pelvic shift, support time, toe-off symmetry, impact, and cadence. Clinical data on hip strength, range of motion, and Kellgren-Lawrence grade were collected.

RESULTS:

Worsening TG severity had a higher mean Kellgren-Lawrence grade (2.5 versus 3.2 versus 3.4; P = .014) and reduced passive hip abduction (P = .004). Severe TG group demonstrated predominantly contralateral pelvic shift (n = 9 of 10, 90.0%), while ipsilateral shift was more frequently detected in moderate (n = 10 of 18, 55.6%) and mild groups (n = 9 of 14, 64.3%; P = .021). Contralateral single support time bias was greatest in severe TG (35.7% versus 50.0 versus 90.0%; P = .027). Asymmetric toe-off, impact, and support times were observed in all groups.

CONCLUSIONS:

Traditional understanding of TG is that truncal shift occurs to the ipsilateral side. Using sensor-based measurements, the present study demonstrates a shift of the weight-bearing axis toward the contralateral side with increasing TG severity, which has not been previously described. Inertial sensors are feasible, quantitative gait measuring tools, and may reveal subtle patterns not readily discernible by traditional methods.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteoartrite do Quadril / Amplitude de Movimento Articular / Análise da Marcha / Marcha Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Osteoartrite do Quadril / Amplitude de Movimento Articular / Análise da Marcha / Marcha Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Arthroplasty Assunto da revista: ORTOPEDIA Ano de publicação: 2024 Tipo de documento: Article